Autonomous Fontan pump: Computational feasibility studyCentral MessagePerspective

open access: yesJTCVS Open
Objective: After Fontan palliation, patients with single-ventricle physiology are committed to chronic circulatory inefficiency for the duration of their lives. This is due in large part to the lack of a subpulmonary ventricle.
Mark D. Rodefeld, MD   +6 more
doaj   +1 more source

Adenosine‐Sensitive Focal Atrial Tachycardia Late After Atriopulmonary Connection Fontan Procedure: A Case Report

open access: yesJournal of Arrhythmia, Volume 42, Issue 3, June 2026.
We describe a case of adenosine‐sensitive focal atrial tachycardia (AT) in a patient late after atriopulmonary connection (APC) Fontan procedure. Radiofrequency application successfully abolished the AT; meanwhile, conversion to total cavopulmonary connection (TCPC) and/or Maze procedure may fail to suppress the AT because the origin was crista ...
Takahiko Kinjo   +4 more
wiley   +1 more source

The Effect of Additional Pulmonary Blood Flow on Timing of the Total Cavopulmonary Connection

open access: yes, 2012
Background. The staged Fontan procedure is used to palliate functionally univentricular hearts. The effect of additional pulmonary blood flow combined with a bidirectional cavopulmonary shunt in these patients remains a controversial subject.
van Melle, Joost P.   +7 more
core   +1 more source

Traditional Atriopulmonary Connection Fontan with Excellent Outcome for 32 Years

open access: yesThe Thoracic & Cardiovascular Surgeon Reports, 2020
Although the traditional right atrial–pulmonary artery (RA–PA) Fontan has been replaced by the total cavopulmonary connection, some RA–PA Fontan patients still have good outcome.
Yong Zhang   +3 more
doaj   +1 more source

Phenotyping of Fontan‐Associated Renal Physiology and Disease

open access: yesComprehensive Physiology, Volume 16, Issue 2, April 2026.
In patients with a Fontan circulation, both kidney function and glomerular injury progressively decline with age, with a stronger decline than in healthy individuals. Additionally, intrarenal haemodynamics in patients with a Fontan circulation demonstrate decreased venous and arterial compliance, evident through elevated venous impedance and renal ...
Gaston van Hassel   +7 more
wiley   +1 more source

Standardized Reporting of Cardiac Magnetic Resonance Examinations in Children With Cardiac Diseases and Adults With Congenital Heart Disease: A Scientific Statement From the Association for European Pediatric and Congenital Cardiology (AEPC) and the International Society for Magnetic Resonance in Medicine (ISMRM)

open access: yes
Journal of Magnetic Resonance Imaging, EarlyView.
Francesca Raimondi   +26 more
wiley   +1 more source

The helpful support of veno‐arterial extracorporeal membrane oxygenation to treat an exceptional systemic‐to‐pulmonary venous shunt: A case report

open access: yesPhysiological Reports, Volume 14, Issue 7, April 2026.
Abstract Systemic‐to‐pulmonary venous shunting is a rare cause of refractory hypoxemia. Its prompt recognition is crucial, as management requires not only etiological treatment but also the restoration of physiological venous return. We report the case of a 40‐year‐old man presenting with dyspnea, cervicothoracic edema, and hypoxemia.
Ludovic van Delden   +6 more
wiley   +1 more source

Pulmonary hepatic flow distribution in total cavopulmonary connections: extracardiac versus intracardiac.

open access: yes, 2018
OBJECTIVE: Pulmonary arteriovenous malformations can occur after the Fontan procedure and are believed to be associated with disproportionate pulmonary distribution of hepatic venous effluent.
Kartik S. Sundareswaran (5061785)   +7 more
core   +1 more source

Hydraulic In Vitro Characterization of MR‐Conditional Blood Pumps

open access: yesArtificial Organs, Volume 50, Issue 3, Page 393-403, March 2026.
Cardiac surgery in neonates requires close placement of cardiopulmonary bypass machines due to limited blood volume, complicating MR compatibility. This study introduces three MR‐conditional blood pump prototypes. None interfered with MRI imaging, though RF‐related sensor effects remain untested.
Dominik T. Schulte   +6 more
wiley   +1 more source

PARTICLE IMAGE VELOCIMETRY MEASUREMENTS OF THE TOTAL CAVOPULMONARY CONNECTION WITH CIRCULATORY FLOW AUGMENTATION [PDF]

open access: yes, 2010
This thesis project examined the interactive fluid dynamics between a blood pump and the univentricular Fontan circulation. 2-D particle image velocimetry (PIV) measurements were conducted on an idealized total cavopulmonary connection (TCPC) with an ...
Chopski, Steven
core   +1 more source