Premium Intraocular Lens Implantation After Laser Vision Correction: An Updated Narrative Review of Biometry, IOL Selection, Visual Outcomes, and Clinical Management. [PDF]
Almulhim A.
europepmc +1 more source
Proteomic analysis of corneal astigmatism identifies reduced apolipoprotein A-IV as a candidate biomarker. [PDF]
Wei X, Li W, Zhang W.
europepmc +1 more source
Effects of SMILE on intraocular pressure and corneal biomechanics: a systematic review and meta-analysis. [PDF]
Lampsas S +4 more
europepmc +1 more source
Outcomes of keraring implantation for high regular astigmatism in non-ectatic corneas: A prospective pilot case series. [PDF]
Mounir A, Mossa EAM, Mahmoud A.
europepmc +1 more source
Evaluation of posterior and total corneal astigmatism with colour-LED topography [PDF]
To characterise the posterior and total corneal astigmatism using colour point-source light-emitting diodes (LED) topography.In a prospective case series 400 eyes from 400 patients were evaluated by colour-LED topography. Only eyes with normal topographies were considered.
Mendes, João +2 more
openaire +4 more sources
Related searches:
Contribution of posterior corneal astigmatism to total corneal astigmatism
Journal of Cataract and Refractive Surgery, 2012To determine the contribution of posterior corneal astigmatism to total corneal astigmatism and the error in estimating total corneal astigmatism from anterior corneal measurements only using a dual-Scheimpflug analyzer.Cullen Eye Institute, Baylor College of Medicine, Houston, Texas, USA.Case series.Total corneal astigmatism was calculated using ray ...
Douglas D, Koch +5 more
openaire +2 more sources
A Longitudinal Study of Corneal Astigmatism and Total Astigmatism
Optometry and Vision Science, 1981Abstract Cross‐sectional studies indicate that mean total astigmatism changes with age; varying from as much as 0.62 D with‐the‐rule during youth to as much as 0.37 D against‐the‐rule in samples of elderly patients. The present study involves the examination of adult patients who were seen regularly for a period of at least 40 years ...
W R, Baldwin, D, Mills
openaire +2 more sources
Corneal Topographic Astigmatism (CorT) to Quantify Total Corneal Astigmatism
Journal of Refractive Surgery, 2015PURPOSE: To evaluate the performance of corneal topographic astigmatism (CorT) based on total corneal power measurements. METHODS: Anterior, posterior, and total corneal power measurements of 526 virgin eyes obtained using the CSO Sirius tomographer (Costuzione Strumenti Oftalmici ...
Noel, Alpins +2 more
openaire +2 more sources
Purpose: To evaluate how closely manufacturer-provided measures of total corneal astigmatism correspond with the manifest refractive cylinder, as compared to a benchmark of corneal topographic astigmatism calculated on the basis of measured total corneal power (TCP) data (CorT Total). Methods:
Noel, Alpins +4 more
openaire +2 more sources

