Results 11 to 20 of about 19,670 (300)
Total Harmonic Distortion Analysis Of Matrix Converter
{"references": ["1.\tM. Imayavaramban, A.V. Krishna Chaitanya and B.G. Fernandes, Analysis and Mathematical Modeling of Matrix Converter for Adjustable Speed AC Drives\u201d, IEEE Trans, PSCE-2006. 2.\tHulusi Karaca, Ramazan Akkaya,\u201d Control of Venturini Method based Matrix converter in Input Voltage Variations\u201d, IMECS 2009, March 18-20, 2009,
K. Kandan, K. Senthilkumar, K. Dhivya
openaire +3 more sources
Total Harmonic Distortion at Fault in RLC Load
<p>This paper focuses on the calculation of total harmonic distortion (THD) at various fault situations in case of RLC load. The faults are created by introducing heavy impedance of 1000 ohm, by blowing off the gate pulse at one of the terminals of the mosfet, and by introducing a line to ground fault. The Matlab based simulation has been done to
Pankaj Aswal +4 more
openaire +3 more sources
This paper shows the implementation of the Moth–Flame Optimization algorithm in a Cascade-H multilevel inverter with five and seven levels to determine the optimal switching sequence of the inverter’s semiconductor devices.
Adolfo R. Lopez +12 more
doaj +2 more sources
Standards of Distorted Signal for Calibration of Total Harmonic Distortion Meters
In this article a survey and evaluation of some progressive approaches to the standards of non-linear distortion is reported. Some types of standards of signals with the known total harmonic distortion used for calibration of distortion measuring ...
P. Horsky
doaj +2 more sources
High Harmonic Reduction Using Passive Filters of Mountain Steel Company
An increasing amount of power electronics has created an immediate effect on the value of the electrical power source. Both of high control manufacturing loads and national loads explain harmonic in the system voltage.
Asmahan Y. Husen +2 more
doaj +1 more source
Feasibility Analysis for Power Transformer Expectancy and Loss of Life “A practical Case Study in Egyptian Electricity Transmission Company” [PDF]
Quality of power supply is now a major worldwide important issue making harmonic analysis an essential element in power system planning and design. Because of the power transformers are major components in power systems; this paper studies the impact of ...
Ibrahim Henidaq +3 more
doaj +1 more source
The industrial revolution in the world resulted in a rise in the desire for energy in recent years. Therefore, the trend was strong toward the utilization of alternative and sustainable energy sources, such as solar power and wind energy.
Mohamed A. Ismeil +3 more
doaj +1 more source
A Proposed Harmonic Monitoring System for Large Power Users Considering Harmonic Limits
Most power utilities within Southern Africa are faced with the challenges of harmonic distortion due to the high penetration of renewable energy sources (RES) and the use of electronic devices.
Rosalia Sinvula +2 more
doaj +1 more source
Standards of distorted signal for calibration of total harmonic distortion meters [PDF]
In this article a survey and evaluation of some progressive approaches to the standards of non-linear distortion is reported. Some types of standards of signals with the known total harmonic distortion used for calibration of distortion measuring instruments are proposed.
openaire +3 more sources
Mitigation of load side harmonic distortion in standalone photovoltaic based microgrid [PDF]
Photovoltaic (PV) system as one part of distributed energy resources is becoming an alternative for low and medium distribution network of microgrid. By the reason of a wide implementation of power electronic and non-linear loads, harmonics distortion is
Aljwary Adel +3 more
doaj +1 more source