Results 91 to 100 of about 7,378,396 (205)
Besarnya distorsi pada semua komponen harmonic disebut dengan Total Harmonic Distortion (THD), pengaruh harmonic terkhususnya untuk motor listrik dalam jangka pendek menyebabkan getaran dan suara pada mesin tersebut yang diakibatkan oleh arus ...
RIVANI, JUAN EGI +2 more
core +1 more source
With the growing integration of electric vehicles, smart grids, and power electronics in power systems, harmonic distortion is becoming a pressing concern, degrading power quality and causing equipment issues that may lead to grid failures.
Tang Bo +3 more
doaj +1 more source
Kerobokan feeder supply electrical energy in the area of Kerobokan. This feeder supplies 67 distribution transformers that serve a variety of customers with nonlinier electrical loads. Nonlinier electrical loads cause harmonics which adversely affect customers and power system equipment, especially distribution transformers. In Kerobokan feeder, only 3
I Wayan Sukerayasa +2 more
openaire +2 more sources
: This research designs controller of logic of fuzzy to control network of switching of at active filter so that can inseminate tension of compensation by precision.
Ahmad Fahmi
doaj +1 more source
In this paper, Artificial Neural Network (ANN) technique has been used for the estimation of voltage THD (Total Harmonic Distortion), current THD and power factor, mainly from input and output measurements of five different chorded induction motors fed ...
BİRBİR, YAŞAR +2 more
core +1 more source
Total Harmonics Distortion (THD) Reduction Techniques in Class D Amplifiers
Class D amplifiers find widespread application in audio devices for driving load speakers, primarily due to their remarkable efficiency. Nonetheless, this enhanced efficiency often comes at the expense of reduced linearity. Hence, techniques for reducing
Huang, Shijie (author)
core
Utilizing the same parameters for operation, 50 Hz frequency, and 380 V line voltage, every single inverter is represented mathematically on the MATLAB/Simulink environment.
Wadhah Hasan
doaj +1 more source
Harmonic mitigation for symmetrical cascaded h-bridge inverter using sparrow search algorithm
Harmonics in multilevel inverters (MLIs) pose a critical challenge in power electronic systems, degrading power quality and complicating compliance with grid standards.
Daniel Igenumah Tennyson +3 more
doaj +1 more source
Active-filter-based power-quality improvement schemes, in general, focus on the reduction of total harmonic distortion (THD) and improvements in power factor (PF). This may not be adequate because standards, such as IEEE-519/IEC 61000, require that apart
George, S. +3 more
core +1 more source
Implementasi Transformator Penggeser Fasa Pada Sistem Distribusi Radial Tiga Fasa Untuk Menurunkan Total Harmonic Distortion (Thd) [PDF]
Beban listrik non-linier merupakan penyebab arus harmonisa pada sistem kelistrikan yang berpengaruh pada kualitas daya listrik dan kerusakan peralatan. Oleh karena itu, diperlukan perhitungan aliran daya harmonisa untuk mengetahui besar dan penyebaran
Stephani, Ribka
core

