Results 91 to 100 of about 6,600 (212)
This study presents the power quality issue mainly focus the effect of total harmonic distortion (THD) on a grid-connected PV system. Firstly, a gridconnected PV system with a single-phase single-stage has been developed to monitor the output values of ...
Nurhazwani Anang, Wan Mariam Wan Muda
core +1 more source
Precision of the Sinefitting-Based Total Harmonic Distortion Estimator
An analytical expression for the standard deviation of Total Harmonic Distortion (THD) estimation is derived. It applies to the case where the estimator uses sine fitting.
Alegria, F. C., Alegria Francisco C.
core +1 more source
Total Harmonic Distortion at Fault in RLC Load
This paper focuses on the calculation of total harmonic distortion (THD) at various fault situations in case of RLC load. The faults are created by introducing heavy impedance of 1000 ohm, by blowing off the gate pulse at one of the terminals of the ...
Aswal, Pankaj +4 more
core +1 more source
Harmonic mitigation for symmetrical cascaded h-bridge inverter using sparrow search algorithm
Harmonics in multilevel inverters (MLIs) pose a critical challenge in power electronic systems, degrading power quality and complicating compliance with grid standards.
Daniel Igenumah Tennyson +3 more
doaj +1 more source
Kebutuhan akan energi saat ini semkain meningkat dengan kegiatan manusia yang banyak menggunakan energi terutama energi listrik. Sehingga perlu tindakan penghematan energi seperti penerangan dengan menggunakan perangkat elektronik yang hemat energi ...
Haryanto, Mulya
core
The effect of using filter on total harmonic distortion in multilevel inverter
Multi-level inverter used in applications that require high power. The important factor in multi-level inverter is Total Harmonic Distortion (THD). This study discuss nine level cascaded H-bridge multilevel inverter.
Abed, Jameel Kadhum +2 more
core +1 more source
Harmonic distortion caused by nonlinear loads is a significant challenge in power systems, often resulting in reduced efficiency, overheating, and equipment malfunction. Despite the availability of various mitigation techniques, many fail to offer a cost-effective and practical solution for distribution networks.
Sulav Shrestha +2 more
openaire +1 more source
Besarnya distorsi pada semua komponen harmonic disebut dengan Total Harmonic Distortion (THD), pengaruh harmonic terkhususnya untuk motor listrik dalam jangka pendek menyebabkan getaran dan suara pada mesin tersebut yang diakibatkan oleh arus ...
RIVANI, JUAN EGI +2 more
core
Kerobokan feeder supply electrical energy in the area of Kerobokan. This feeder supplies 67 distribution transformers that serve a variety of customers with nonlinier electrical loads. Nonlinier electrical loads cause harmonics which adversely affect customers and power system equipment, especially distribution transformers. In Kerobokan feeder, only 3
I Wayan Sukerayasa +2 more
openaire +2 more sources
Effects of Total Harmonic Distortion on Power System Equipment
Total harmonic distortion, or THD, is the summation of all harmonic components of the voltage or current t waveform compared against the fundamental component of the voltage or current wave: Harmonic is a sinusoidal component of a periodic wave or ...
AJENIKOKO, GANIYU ADEDAYO. +1 more
core

