Results 71 to 80 of about 7,236,039 (281)
Dynamic Disulfide Ionogels for Self‐Healing, Transparent, and Elastic E‐Skins
A dynamic covalent ionogel is designed via polymer–ionic liquid interaction control. The interplay between ionic liquid compatibility, viscosity, and concentration governs polymer segmental dynamics, which in turn regulates disulfide exchange kinetics and mechanical durability.
Min Su Kim +6 more
wiley +1 more source
Use of Topical (Intra-articular) Tranexamic Acid to Minimise Blood Loss and Transfusion in Total Knee Replacement Surgery [PDF]
Introduction Total knee replacement (TKR) is a common orthopaedic procedure, with 20-70% of patients needing 1-3 units of blood, although allogeneic transfusion is not risk free.
ALSHRYDA, SATTAR,JABER,MOHR +1 more
core
Pak Biawak, a necrobot, embodies an unusual fusion of biology and robotics. Designed to repurpose natural structures after death, it challenges conventional boundaries between nature and engineering. Its movements are precise yet unsettling, raising questions about sustainability, ethics, and the untapped potential of biointegrated machines.
Leo Foulds +2 more
wiley +1 more source
Compliant Pneumatic Feet with Real‐Time Stiffness Adaptation for Humanoid Locomotion
A compliant pneumatic foot with real‐time variable stiffness enables humanoid robots to adapt to changing terrains. Using onboard vision and pressure control, the foot modulates stiffness within each gait cycle, reducing impact forces and improving balance. The design, cast in soft silicone with embedded air chambers and Kevlar wrapping, offers durable,
Irene Frizza +3 more
wiley +1 more source
Background: Total knee arthroplasty (TKA) has an excellent success rate for the treatment of advanced arthritis of the knee. Component malrotation is one of the main causes of poor outcomes.
Aaditya Chandel +2 more
doaj +1 more source
Muscle Control of an Extra Robotic Digit
This study compares muscle‐ and movement‐based control for operating a supernumerary robotic thumb. While movement control performs better in the proposed tasks, muscle‐based (EMG) control promotes broader motor learning. The results highlight the promise and challenges of using biosignals for human augmentation, offering new insights into intuitive ...
Julien Russ +7 more
wiley +1 more source
Incidence of Total Knee Replacement after Knee Arthroscopy over the age of 50 years.
Objectives: This paper will look at the incidence of Total Knee Replacement in patients over the age of 50 years over an 8 year period. All patients had a symptomatic medial meniscal tear and moderate bi-compartmental osteo-arthritis.
Mr Tony Robinson, Ms Tracy Robertson
doaj +1 more source
Total replacement of the knee [PDF]
M, Tew, W, Waugh
openaire +2 more sources
Multimodal Human–Robot Interaction Using Human Pose Estimation and Local Large Language Models
A multimodal human–robot interaction framework integrates human pose estimation (HPE) and a large language model (LLM) for gesture‐ and voice‐based robot control. Speech‐to‐text (STT) enables voice command interpretation, while a safety‐aware arbitration mechanism prioritizes gesture input for rapid intervention.
Nasiru Aboki +2 more
wiley +1 more source
Standardized loads acting in knee implants [PDF]
The loads acting in knee joints must be known for improving joint replacement, surgical procedures, physiotherapy, biomechanical computer simulations, and to advise patients with osteoarthritis or fractures about what activities to avoid. Such data would
Bergmann, Georg +15 more
core +1 more source

