Results 101 to 110 of about 24,284 (286)

Buckling‐Driven Linearity in Flexible Capacitive Pressure Sensors Based on a Three‐Dimensional Dual‐Pore Polyurethane Structure

open access: yesAdvanced Materials Technologies, EarlyView.
A flexible pressure sensor utilizing a 3D dual‐pore polyurethane structure is developed to overcome the intrinsic trade‐off between sensitivity and linearity. By inducing sequential buckling through distinct pore sizes and shapes, the device achieves highly linear and sensitive responses across a wide pressure range.
Jae Yeong Jang, Jaemin Choi, Young Jung
wiley   +1 more source

A capacitive air touch sensor system in 65nm CMOS technology [PDF]

open access: yes, 2012
In this thesis, the new methodology of an oscillator-based capacitive air touch sensor system is introduced for future touch screen technology. This high sensitivity and low power solution is based on oscillation frequency shifts for air touch screening ...
Hsieh, Ying-Ying
core  

Flexible AlN Coupled MOSFET Device for Touch Sensing

open access: yes, 2018
This work presents touch sensing device with flexible piezoelectric Aluminium Nitride (AIN) capacitor tightly coupled with a MOSFET device. Unlike conventional high-temperature deposition, the A1N in this work was sputtered on polyimide at room ...
Leandro Lorenzelli   +9 more
core   +1 more source

Flexible Pressure Sensor With Co‐Optimized Sensitivity and Linearity Based on Gradient Toroidal Microstructures

open access: yesAdvanced Materials Technologies, EarlyView.
A flexible piezoresistive pressure sensor with gradient toroidal CNT/PDMS microstructures is reported. The hierarchical geometry enables sequential electrode contact, achieving a sensitivity of 256.20 kPa−1 and linear response (R2 = 0.99) over 0–1000 kPa.
Rongmei Wang   +8 more
wiley   +1 more source

Estimation of the Values of Electrical Shock Currents during Live-Line Work in Multi-Circuit, Multi-Voltage HVAC Transmission Lines

open access: yesEnergies
This article covers the analysis of voltages induced on the conductors of a de-energized circuit of a multi-circuit, multi-voltage HVAC transmission line.
Agnieszka Dziendziel
doaj   +1 more source

Coral Rock Thickness Grounding System Switchyard Substation In Clay

open access: yesJournal of Electrical, Electronics and Informatics, 2023
The grounding of the equipment at the substation switchyard location is given a layer of coral about 10 cm above the ground surface to reduce the tension difference on the ground surface and increase the resistance of the human feet around it.
IGN Janardana, I Wayan Arta Wijaya
doaj  

Soft Robotic Excretory Care Simulator for Nursing Education: Functional and Perceptual Biomimetics Approach

open access: yesAdvanced Robotics Research, EarlyView.
A soft robotic simulator is developed to replicate the digital removal of feces (DRF), a sensitive yet essential nursing procedure. Integrating soft actuators, sensors, and a realistic rectal model, the simulator balances functional fidelity with perceptual realism. Engineering evaluations and nurse feedback confirm its potential to enhance training in
Shoko Miyagawa   +10 more
wiley   +1 more source

Development of an Algorithm and Software “MVES-TV 2012” for Touch Voltage Evaluation in MV Networks

open access: yes
The paper presents an algorithm for evaluation of touch voltage in medium voltage networks with different types of neutral earthing. The proposed algorithm takes into account power line type (overhead line, underground cable line), earth fault value ...
Priedīte, Ilze, Rozenkrons, Jānis
core  

From Rigid to Soft Robotic Approaches for Neuroendoscopy

open access: yesAdvanced Robotics Research, EarlyView.
Robotic assistance has had minimal impact on deep intraventricular surgeries, where small‐scale, precision, and reduced invasiveness can contribute to improved patient outcomes. Emerging technologies in rigid, soft, and hybrid robotics are reviewed to identify the most promising mechanisms for deep brain navigation in addition to an attempt to identify
Kieran Gilday   +3 more
wiley   +1 more source

Modulus‐Switchable Miniature Robots for Biomedical Applications: A Review

open access: yesAdvanced Robotics Research, EarlyView.
Materials, robot designs, proof‐of‐concept functions, and biomedical applications of modulus‐switchable miniature robots. Miniature soft robots have shown great potential in biomedical applications due to their excellent controllability and suitable mechanical properties in biological environments.
Chunyun Wei, Yibin Wang, Jiangfan Yu
wiley   +1 more source

Home - About - Disclaimer - Privacy