Results 201 to 210 of about 19,206 (299)

Design and Application of Strong and Tough Low-Friction Hydrogels. [PDF]

open access: yesGels
Wei X   +7 more
europepmc   +1 more source

Low‐Temperature Solid‐State Sintering of High‐Strength and Electrically Conductive Silicon Carbide With Direct Current Flow and In Situ Graphitization

open access: yesRare Metals, Volume 45, Issue 11, November 2026.
ABSTRACT Silicon carbide (SiC) is an ultra‐hard ceramic material and is intrinsically difficult to sinter. Pressureless solid‐state sintering (PS) typically requires high temperatures exceeding 2200°C and a prolonged heating cycle, whereas liquid‐phase sintering lowers the processing temperature at the expense of high‐temperature mechanical performance.
Meicen Fan   +5 more
wiley   +1 more source

Mortise-and-tenon like van der Waals joints for strong and tough materials via multi-flow microfluidics. [PDF]

open access: yesNat Commun
Cai G   +10 more
europepmc   +1 more source

Sintering Behavior and Microstructure Analysis of Polycrystalline Monoclinic Zirconia

open access: yesJournal of the American Ceramic Society, Volume 109, Issue 11, November 2026.
ABSTRACT Zirconia transforms into different phases depending on the temperature, with the monoclinic phase being thermodynamically stable below approximately 1170°C. However, fabricating a dense m‐phase zirconia polycrystal is challenging due to the elevated temperature required for densification, which inevitably triggers the monoclinic‒tetragonal ...
KyungHyeon Yoo   +6 more
wiley   +1 more source

Effect of Glazing Dwell Time and Cooling Duration on Flexural Strength and Surface Microhardness of 3 mol% Yttria‐Stabilized Tetragonal Zirconia: An In Vitro Study

open access: yesJournal of Esthetic and Restorative Dentistry, Volume 38, Issue 11, Page 2199-2206, November 2026.
ABSTRACT Objective To evaluate the effect of glazing dwell time and cooling duration on the flexural strength and surface microhardness of high‐translucency 3 mol% yttria‐stabilized tetragonal zirconia polycrystal (3Y‐TZP). Materials and Methods Total of 108 rectangular zirconia specimens (20 × 4 × 2 mm) were fabricated from preshaded monolithic blocks
Shubha Sarmalkar   +5 more
wiley   +1 more source

Long‐Term Clinical and Radiographic Outcomes of Ceramic Dental Implants: An 11‐Year Retrospective Cohort Study

open access: yesJournal of Esthetic and Restorative Dentistry, Volume 38, Issue 11, Page 2074-2088, November 2026.
ABSTRACT Objective Evidence on zirconia dental implants remains limited. This retrospective study evaluated clinical and radiographic outcomes of contemporary ceramic implant systems placed in private practice with variable follow‐up of up to 11 years.
Mona Monzavi   +3 more
wiley   +1 more source

Activating Phase-Transition Toughening in van der Waals Semiconductor GaTe. [PDF]

open access: yesNano Lett
Xu R   +13 more
europepmc   +1 more source

Home - About - Disclaimer - Privacy