Results 41 to 50 of about 1,529,744 (164)

iStent: Trabecular Micro-Bypass Stent [PDF]

open access: yes, 2020
AbstractWithin the class of procedures termed minimally invasive glaucoma surgery (MIGS), the iStent Trabecular Micro-Bypass Stent (Glaukos Corporation, San Clemente, CA, USA) is an intraocular implant that resides within Schlemm’s canal and allows for direct bypass of the trabecular meshwork by aqueous fluid.
Christine L. Larsen, Thomas W. Samuelson
openaire   +1 more source

Clinical Outcomes of Trabecular Micro-Bypass Stent in Patients with Moderate-to-Severe Open-Angle Glaucoma. [PDF]

open access: yesKorean J Ophthalmol
To evaluate 1-year clinical outcomes and response markers after implantation of a trabecular micro-bypass stent (iStent inject® W) in patients with moderate-to-severe open-angle glaucoma (OAG).This retrospective cohort study included 22 eyes of 22 patients with moderate-to-severe OAG who underwent standalone iStent inject® W implantation (n = 4) or ...
Yang S, Lee J, Lee SM, Lee JE, Moon S.
europepmc   +3 more sources

Comparative Effectiveness and Safety of Two Different Trabecular MIGS Devices With and Without Ab Interno Canaloplasty in Patients with Primary Open-Angle Glaucoma

open access: yesOphthalmology and Therapy, 2023
Introduction This study compared outcomes of the iStent inject trabecular micro-bypass system versus the Hydrus Microstent in patients with primary open-angle glaucoma (POAG). Methods Forty subjects (80 eyes) with POAG were included in this single-center,
Mitchell Shultz   +2 more
doaj   +1 more source

Mid-term evaluation of the safety and efficacy of the iStent trabecular micro-bypass system combined with phacoemulsification [PDF]

open access: yesAdvances in Clinical and Experimental Medicine, 2021
Micro-invasive glaucoma surgery (MIGS) and MIGS devices have been gaining increasing attention in recent years. One such device is the trabecular micro-bypass stent, or iStent® (Glaukos Corporation, Laguna Hills, USA).To evaluate the safety and efficacy of the minimally invasive ab interno surgical implantation of a trabecular bypass during cataract ...
Milena Kozera   +2 more
openaire   +2 more sources

7-Year Efficacy and Safety of iStent inject Trabecular Micro-Bypass in Combined and Standalone Usage. [PDF]

open access: yesAdv Ther
This study evaluated 7-year effectiveness and safety of second-generation trabecular micro-bypass implantation (iStent inject) either in combination with cataract surgery or as a standalone procedure (Combined or Standalone subgroups, respectively) in eyes with open-angle glaucoma.This prospective, non-randomized, unmasked, longitudinal study included ...
Hengerer FH   +2 more
europepmc   +3 more sources

Trabecular Bone Structure Correlates with Hand Posture and Use in Hominoids [PDF]

open access: yes, 2013
Bone is capable of adapting during life in response to stress. Therefore, variation in locomotor and manipulative behaviours across extant hominoids may be reflected in differences in trabecular bone structure.
Smaers, JB   +45 more
core   +1 more source

Preventing glaucoma progression using the trabecular micro-bypass implant iStent inject®. A cost-effectiveness analysis

open access: yesRevista Brasileira de Oftalmologia, 2021
Objective To assess the economic impact of reducing glaucoma progression by using the trabecular micro-bypass implant, iStent inject®, in the Reference Centers for glaucoma treatment within the Brazilian Public Unified Health System (SUS).
Ricardo Augusto Paletta Guedes   +5 more
doaj   +1 more source

3D analysis from micro-MRI during in situ compression on cancellous bone. [PDF]

open access: yes, 2009
The authors would like to acknowledge Claude Verliac and Joachim Magnier for technical advice on the manufacturing process of the mechanical loading system.A mini-compression jig was built to perform in situ tests on bovine trabecular bone monitored by ...
GUÉRARD, Sandra   +8 more
core   +1 more source

Glaukos iStent ® trabecular micro-bypass

open access: yesMiddle East African Journal of Ophthalmology, 2009
The iStent trabecular micro-bypass system (Glaukos Corp. Laguna Hills, CA) was developed to address the limitations of current medical and surgical therapies for glaucoma treatment. The iStent((R)) is inserted ab interno through a small temporal clear corneal incision, bypassing the trabecular meshwork and placed in Schlemm's canal at the lower nasal ...
openaire   +3 more sources

Micro-CT analyses of trabecular bone microarchitecture in the distal femoral metaphysis.

open access: yes, 2022
A) Representative 3D images of the femoral trabecular bone architecture scanned by micro-CT. B) The distal femoral metaphysis was scanned in an area 2.8–3.0 mm proximal to the distal end of the femur, including the border between the metaphysis and ...
Hak-Jin Choi (12506063)   +2 more
core   +1 more source

Home - About - Disclaimer - Privacy