Results 51 to 60 of about 6,001 (210)

Same‐Day Discharge After Transcatheter Aortic Valve Implantation: Who, When, and How?

open access: yesCatheterization and Cardiovascular Interventions, Volume 108, Issue 3, Page 816-823, September 1, 2026.
ABSTRACT The burden of severe aortic stenosis requiring treatment is growing due to ageing populations. This places increased demands on health resources due to the growing number of transcatheter aortic valve implantation (TAVI) procedures and hospital bed occupancy.
Hilal Khan   +8 more
wiley   +1 more source

The Systolic Anterior Motion After Mitral Valve Repair: A Narrative Review of Current Therapeutic Algorithms in the Operating Room

open access: yesHealth Science Reports, Volume 9, Issue 9, September 2026.
ABSTRACT Background and Aims Systolic anterior motion (SAM) represents the displacement of the anterior mitral leaflet during ventricular systole toward the interventricular septum, causing an obstruction of the outflow tract. Most of the published data regards the primary SAM that is associated with hypertrophic cardiomyopathy. This review was focused
Carmen Elena Opris   +5 more
wiley   +1 more source

Cerebrovascular Events in Aortic Stenosis: From Native Valve Disease to TAVR‐Specific Risk and Prevention

open access: yesCatheterization and Cardiovascular Interventions, Volume 108, Issue 2, Page 331-342, August 1, 2026.
ABSTRACT Aortic stenosis (AS) is associated with a heightened burden of cardiovascular comorbidities, atrial fibrillation (AF), and progressive valvular calcification, all of which may contribute to cerebrovascular events across the disease continuum.
Priyanka Boettger   +7 more
wiley   +1 more source

Transapical NeoChord mitral valve repair [PDF]

open access: yesAnnals of Cardiothoracic Surgery, 2018
Transapical off-pump mitral valve repair (MVr) with NeoChord implantation has become widely applied in Europe for patients presenting with severe mitral regurgitation due to leaflet prolapse or flail. The procedure is performed under real-time 2D- and 3D-transesophageal echocardiography (TEE) for both implantation and neochordae tension adjustment ...
Colli A   +7 more
openaire   +3 more sources

Annular Ellipticity and Sizing Strategy in Transcatheter Aortic Valve Implantation: Independent or Combined Risk Patterns?

open access: yesCatheterization and Cardiovascular Interventions, Volume 107, Issue 6, Page 1774-1781, May 1, 2026.
ABSTRACT Background Elliptical annular anatomy has been considered a risk factor for adverse outcomes after TAVI, particularly paravalvular leakage (PVL). Prosthesis oversizing is thought to improve sealing, but the interaction between annular shape and sizing strategy remains unclear.
Emre Polat   +6 more
wiley   +1 more source

A challenging double bubble thoracic aortic and proximal subclavian aneurysm treated via transapical access

open access: yesJournal of Vascular Surgery Cases and Innovative Techniques, 2020
This case report describes a patient with a distal aortic arch and left subclavian artery aneurysm who was considered unsuitable for open surgical repair because of comorbidities and previous bypass surgery.
Hector W. de Beaufort, MD, PhD   +2 more
doaj   +1 more source

Reparación de la válvula mitral sin circulación extracorpórea con neocuerdas por vía transapical. Experiencia inicial

open access: yesCirugía Cardiovascular, 2023
Resumen: Introducción: La reparación mitral sin circulación extracorpórea, con implante de neocuerdas por vía transapical (TOP MINI) es un procedimiento eficaz y reproducible para el tratamiento de la insuficiencia mitral degenerativa.
Daniel Pérez-Camargo   +7 more
doaj   +1 more source

TAVR in Male Patients With Large Aortic Valve Annuli: A Propensity‐Matched Analysis of Balloon‐Expandable Versus Self‐Expanding Valves

open access: yesCatheterization and Cardiovascular Interventions, Volume 107, Issue 5, Page 1506-1513, April 1, 2026.
ABSTRACT Background Trans‐catheter aortic valve replacement (TAVR) in patients with large annuli poses procedural difficulties and possible complications. Aims We sought to compare the peri‐procedural and long‐term outcomes of patients with large annuli undergoing TAVR with self‐expanding (SEV) versus balloon‐expandable (BEV) valves.
Lior Zornitzki   +12 more
wiley   +1 more source

Urgent reoperative transapical valve-in-valve shortly after a transapical aortic valve implantation [PDF]

open access: yes, 2017
Urgent reoperative transapical aortic valve-in-valve has never been proposed as a treatment option in case of a failed transcatheter aortic valve implantation (TAVI) or in case of worsening of an existing paravalvular leak, if this complication occurs ...
Locca, Didier   +3 more
core  

Closure of apical access site after transapical, transcatheter paravalvular leak closure

open access: yes, 2012
The safety of percutaneous transapical mitral paravalvular leak (PVL) closure could potentially be enhanced by device closure of the ventricular access site. Percutaneous transapical PVL closure was performed.
Osswald, Stefan   +5 more
core   +1 more source

Home - About - Disclaimer - Privacy