Results 1 to 10 of about 84,994 (214)
A Transcatheter Closure of Large-Size Patent Ductus Arteriosus with Severe Degree of Pulmonary Hypertension by Different Types of Devices [PDF]
Background: Transcatheter closure is the most common treatment for patent ductus arteriosus (PDA); however employing large PDA is difficult because there are few closure devices, and surgical treatment is risky, especially in young infants with low ...
Mohanad K Shukur Al Ghanimi +2 more
doaj +1 more source
Emergency TAVI in a critically ill patient: A case report
Transcatheter aortic valve implantation is a safe procedure even in inoperable patients with multi‐organ failure and cardiogenic shock. In such cases, the heart team should be prepared to proceed to emergent implantation for timely and successful ...
Konstantinos Papadopoulos +5 more
doaj +1 more source
Background: Ventricular Septal Defect is a Congenital Heart Defect characterized by an opening in interventricular septum or more that happen because of intraventricular septum’s failure to fuse during fetal development.
Alvin Ivander +3 more
doaj +1 more source
Objective: With expanding eligibility criteria, transcatheter aortic valve replacement is being performed on patients with longer life expectancy, and subsequent procedures after index transcatheter aortic valve replacement are inevitable.
Paige Newell, MD +10 more
doaj +1 more source
AimsFor patients with severe mitral valve regurgitation (MR), different kinds of transcatheter mitral valve repair (TMVr) exist, targeting the leaflets, annulus, and chordae.
Hiroaki Yokoyama +9 more
doaj +1 more source
MitraClip and left ventricular reverse remodelling: a strain imaging study
Aims The purpose of this study is to identify echocardiography predictors of clinical response and reverse left ventricular (LV) remodelling in patients with functional mitral regurgitation (FMR) treated with MitraClip.
Konstantinos Papadopoulos +6 more
doaj +1 more source
Background Until recently, a large right ventricle outflow tract interfered with the feasibility of standard transcatheter pulmonary valve replacement (PVR).
Kaitlin Carr +6 more
doaj +1 more source
Valve-in-valve implantation for dysfunctional bioprosthetic valves has been shown to be a safe and feasible option for selected patients (Dvir et al., 2014, Bapat et al., 2012, Piazza et al., 2011).
A.B. Gopalamurugan +4 more
doaj +1 more source
A 64-year-old female underwent a successful first percutaneous intervention using MISAGO stents for a de novo femoropopliteal lesion. Subsequently, three more effective procedures were done using balloon catheters for in-stent restenosis.
Taketsugu Tsuchiya +6 more
doaj +1 more source
Tricuspid Leaflet Gap-Reduction Maneuvers During Transcatheter Tricuspid Valve Repair
Transcatheter tricuspid valve edge-to-edge repair (T-TEER) has emerged as an option for treating patients with tricuspid regurgitation. Few studies have explored intraprocedural maneuvers to optimize leaflet-grasping T-TEER in order to improve technical ...
Carlos Godoy Rivas, MD +5 more
doaj +1 more source

