Results 1 to 10 of about 89,233 (267)
Emergency TAVI in a critically ill patient: A case report
Transcatheter aortic valve implantation is a safe procedure even in inoperable patients with multi‐organ failure and cardiogenic shock. In such cases, the heart team should be prepared to proceed to emergent implantation for timely and successful ...
Konstantinos Papadopoulos +5 more
doaj +1 more source
A Transcatheter Closure of Large-Size Patent Ductus Arteriosus with Severe Degree of Pulmonary Hypertension by Different Types of Devices [PDF]
Background: Transcatheter closure is the most common treatment for patent ductus arteriosus (PDA); however employing large PDA is difficult because there are few closure devices, and surgical treatment is risky, especially in young infants with low ...
Mohanad K Shukur Al Ghanimi +2 more
doaj +1 more source
Mitral annular calcification with mitral valve disease is a challenging problem that could necessitate surgical mitral valve replacement (SMVR). Transcatheter mitral valve replacement (TMVR) is emerging as a feasible alternative in high‐risk patients ...
Sophia L. Alexis +13 more
doaj +1 more source
Application of and Prospects for 3-Dimensional Printing in Transcatheter Mitral Valve Interventions
Mitral valve (MV) disease is one of the most common valvular diseases that endangers health status. A variety of catheter-based interventions have been developed to treat MV disease.
Yu Mao, Yang Liu, Mengen Zhai, Jian Yang
doaj +1 more source
Respiratory Trajectory after Invasive Interventions for Patent Ductus Arteriosus of Preterm Infants
Invasive interventions have been conducted in preterm infants with significant patent ductus arteriosus (PDA) when medical treatment has failed, and methods of invasive intervention have been reported. Surgical ligation via lateral thoracotomy has been a
Yu-Jen Wei +7 more
doaj +1 more source
MitraClip and left ventricular reverse remodelling: a strain imaging study
Aims The purpose of this study is to identify echocardiography predictors of clinical response and reverse left ventricular (LV) remodelling in patients with functional mitral regurgitation (FMR) treated with MitraClip.
Konstantinos Papadopoulos +6 more
doaj +1 more source
Similar 5-Year Survival in Transfemoral and Transapical TAVI Patients: A Single-Center Experience
Transapical transcatheter aortic valve implantation (TA-TAVI) is generally considered to be associated with increased morbidity and mortality compared with transfemoral transcatheter aortic valve implantation TAVI (TF-TAVI). We aimed to compare different
Constantin Mork +6 more
doaj +1 more source
Valve-in-valve implantation for dysfunctional bioprosthetic valves has been shown to be a safe and feasible option for selected patients (Dvir et al., 2014, Bapat et al., 2012, Piazza et al., 2011).
A.B. Gopalamurugan +4 more
doaj +1 more source
A 64-year-old female underwent a successful first percutaneous intervention using MISAGO stents for a de novo femoropopliteal lesion. Subsequently, three more effective procedures were done using balloon catheters for in-stent restenosis.
Taketsugu Tsuchiya +6 more
doaj +1 more source
Bioprosthetic valve dysfunction leading to haemodynamically significant consequences is well recognised. Traditional treatment of choice has been conventional re-do surgical valve replacement. However, over the last decade, percutaneous solutions such as
A.B. Gopalamurugan +2 more
doaj +1 more source

