Real‐World Comparison of Vascular Access Closure Strategies in TAVI
Catheterization and Cardiovascular Interventions, EarlyView.
Saif Zako +9 more
wiley +1 more source
Sonographic Diagnosis of an Intercostal Artery Pseudoaneurysm: A Case Report and Literature Review
A 63‐year‐old male presented to the emergency department after being found unconscious during a welfare check. Following a prolonged three‐month hospital admission, the patient developed left flank pain. Spectral Doppler ultrasound revealed a large isoechoic lesion with layering echoes, and spectral Doppler demonstrated bidirectional flow.
Aaditya P. Singh, Peter R. Coombs
wiley +1 more source
Cost effectiveness of aortic valve therapies: a systematic review of the literature
Background: we performed a systematic review on the cost effectiveness of transcatheter aortic valve implantation (TAVI) to standard aortic valve replacement and medical management in high-risk elderly patients with severe aortic stenosis. Methods:
Suzanne Battaglia +2 more
doaj
Transcatheter Aortic Valve Implantation Bailout for Severe Aortic Insufficiency due to Aortic Root Dissection Following Ascending Aortic Aneurysm Repair [PDF]
This novel case documents the successful use of transcatheter aortic valve implantation to treat severe aortic insufficiency arising from aortic root dissection following the repair of an ascending aortic aneurysm in a 75-year-old female patient.
Alejandro Sanchez-Nadales, MD +4 more
doaj +1 more source
Balloon Aortic Valvuloplasty as Bridge-to-Decision in High Risk Patients with Severe Aortic Valve Stenosis [PDF]
Background. A sizable group of patients with symptomatic aortic stenosis (AS) can undergo neither surgical aortic valve replacement (AVR) nor transcatheter aortic valve implantation (TAVI) because of clinical contraindications.
Bordoni, Barbara <1980>
core +1 more source
Central illustration: Sex‐based differences in outcomes between male and female patients with bicuspid aortic stenosis following transcatheter aortic valve replacement. Abstract Bicuspid aortic valve (BAV) is a common congenital anomaly leading to early aortic stenosis.
Muhammad Huzaifa Ahmed Khan +12 more
wiley +1 more source
Prognostic value of the ratio between prothesis area and indexed annulus area measured by multiSlice-CT for transcatheter aortic valve implantation procedures [PDF]
Background Postprocedural aortic regurgitations following transcatheter aortic valve implantation (TAVI) procedures remain an is- sue. Benefit of oversizing strategies to prevent them isn’t well established.
Bical A +8 more
core
Background and Purpose Musclin (osteocrin) is a skeletal muscle‐derived peptide that has been implicated in cardioprotective signalling pathways. Its relevance in cancer patients, who frequently experience muscle wasting and cardiotoxicity, remains unclear. This study aimed to determine whether circulating Musclin levels reflect functional capacity and
Jannek Brauer +5 more
wiley +1 more source
Background Transcatheter aortic valve implantation has become an accepted treatment modality for inoperable or high-risk surgical patients with symptomatic severe aortic stenosis.
Shahram Lotfi +5 more
doaj +1 more source
Computer Vision Techniques for Transcatheter Intervention [PDF]
Minimally invasive transcatheter technologies have demonstrated substantial promise for the diagnosis and treatment of cardiovascular diseases. For example, TAVI is an alternative to AVR for the treatment of severe aortic stenosis and TAFA is widely used
Matt Roach, Xianghua Xie
core +1 more source

