Results 91 to 100 of about 918,002 (207)
In an independent multicenter cohort of 951 patients undergoing echocardiography, a deep learning model analyzing an 8‐s heart sound and ECG recording detected moderate‐or‐greater aortic stenosis with 92.9% sensitivity and 87.9% specificity. This approach may support the decision to refer patients from auscultation to echocardiography.
Shumpei Saito +23 more
wiley +1 more source
Aortic valve replacement after bypass surgery: surgical (SAVR) or transcatheter (TAVR) [PDF]
The situation where a patient who has undergone bypass surgery then develops significant aortic valve disease sometime during their subsequent lifetime is common. Previously the treatment choices were medical management or surgical reoperation for aortic valve replacement (SAVR).
openaire +2 more sources
Aortic valve versus root surgery after failed transcatheter aortic valve replacement
We sought to determine outcomes of aortic valve replacement (AVR) versus root replacement after transcatheter AVR (TAVR) explantation because they remain ...
Zaid, Syed +7 more
core +1 more source
ABSTRACT Background Epicardial adipose tissue volume (EATV) is increasingly recognized as a cardiometabolic risk marker associated with adverse outcomes. The most established approach for EATV quantification is cardiac computed tomography (CT). MRI offers a radiation‐free alternative allowing simultaneous assessment of myocardial function and tissue ...
Judith Gronwald +10 more
wiley +1 more source
LVAD‐associated aortic regurgitation impairs circulatory support, with limited surgical and off‐label options. In a multicenter registry (n = 30), the AR‐dedicated JenaValve Trilogy TAVR eliminated AR, achieving 96.7% (29/30) technical success and 93.3% (28/30) device success (VARC‐3), with 3.3% (1/30) 30‐day mortality.
Hristian Hinkov +13 more
wiley +1 more source
Background The performance of transcatheter aortic valve replacement (TAVR) in patients with pre-existing prosthetic mitral valves is technically challenging due to the potential interference between both prosthetic devices.
Oyewole A. Kushimo +4 more
doaj +1 more source
ABSTRACT Background Pulmonary valve replacement is frequently required in adults with congenital heart disease (CHD). Comparative real‐world outcomes between percutaneous transcatheter pulmonary valve implantation (TPVR) and surgical pulmonary valve replacement (SPVR) remain incompletely characterized. We evaluated outcomes and resource utilization for
Adam Bolad +4 more
wiley +1 more source
Key Clinical Message Underexpansion of an aortic bioprosthetic valve is common after transcatheter aortic valve replacement (TAVR). Significant discrepancy between invasive hemodynamic gradients and echocardiographic Doppler gradients in an underexpanded
Imad Hameedullah +3 more
doaj +1 more source
Background Valve-in-Valve (VIV) Transcatheter Aortic Valve Replacement (TAVR) is now the treatment of choice in high-surgical-risk patients with failing aortic bioprosthesis. Although less performed, VIV-Transcatheter Mitral Valve Replacement (TMVR) is a
Marco Zanobini +7 more
doaj +1 more source
ABSTRACT Severe aortic stenosis (AS) carries a poor prognosis when symptomatic, particularly in cardiogenic shock (CS). Emergency transcatheter aortic valve replacement (TAVR) is rarely performed but may represent a rescue therapy. Coexistent carotid artery stenosis (CAS) further increases procedural risk.
Max Groche +3 more
wiley +1 more source

