Results 31 to 40 of about 101,460,446 (165)

1-Year Outcomes After Edge-to-Edge Valve Repair for Symptomatic Tricuspid Regurgitation: Results From the TriValve Registry. [PDF]

open access: yes, 2019
OBJECTIVES The purpose of this study was to evaluate procedural and 1-year clinical and echocardiographic outcomes of patients treated with tricuspid edge-to-edge repair.
Brugger, Nicolas   +37 more
core   +2 more sources

Short‐Term Effects of Different Transcatheter Edge‐to‐Edge Devices on Mitral Valve Geometry

open access: yesJournal of the American Heart Association: Cardiovascular and Cerebrovascular Disease, 2023
Background Short‐term effects on mitral valve (MV) anatomy after transcatheter edge‐to‐edge repair using the PASCAL system remain unknown. Precise quantification might allow for an advanced analysis of predictors for mean transmitral gradients.
Sebastian Rosch   +14 more
doaj   +1 more source

Quality of life after transcatheter edge-to-edge mitral valve repair: A prospective observational cohort study

open access: yesAnnales Academiae Medicae Silesiensis
Introduction: In patients with heart failure (HF), left ventricular remodelling can lead to secondary mitral regurgitation (SMR), which exacerbates HF symptoms and reduces quality of life (QoL). Transcatheter edge-to-edge repair (TEER), an interventional
Tomasz Gallina   +5 more
doaj   +1 more source

Immediate single-leaflet device detachment in a patient with marfan syndrome treated with bail-out edge-to-edge mitral valve repair

open access: yesHeart Views, 2022
Mitral transcatheter edge-to-edge repair (MTEER) is the first transcatheter technique for mitral valve repair (MVR) in patients with severe mitral regurgitation (MR) who are considered at high risk for surgical intervention.
Khaled Al Khodari   +3 more
doaj   +1 more source

Transcatheter edge-to-edge mitral valve repair: what is the measure of success?

open access: yes, 2019
Transcatheter edge-to-edge mitral valve repair: what is the measure of ...
Pesarini, Gabriele   +3 more
core   +1 more source

Volumetric intracardiac echocardiography (vICE) is feasible for procedural guidance of transcatheter mitral edge-to-edge repair (mTEER) [PDF]

open access: yes, 2023
Transcatheter mitral edge-to edge repair(mTEER) is a minimally invasive, catheter-based therapy used to treat mitralregurgitation. The gold standard for intraprocedural guidance of mTEER is transesophageal echocardiography (TEE).4-dimensional volumetric ...
Pham, Tai, Tso, Jade, Singh, Gagan D
core   +1 more source

Update on the Current Status and Indications for Transcatheter Edge-to-Edge Mitral Valve Repair

open access: yes, 2020
PURPOSE OF REVIEW: To review the current status and indications of transcatheter edge-to-edge mitral valve repair. RECENT FINDINGS: Mitral regurgitation remains a common valvular disease and can be classified as degenerative (primary) or functional ...
Chhatriwalla, Adnan K, Qintar, Mohammed
core   +1 more source

Ultra‐Radiostable Covalent Conformationally Interlocked Networks Enabling a Universal Radiometal‐Labeling Platform for Cancer Radioembolization

open access: yesAdvanced Science, EarlyView.
Conjugated poly(imide dioxime)‐based microspheres establish a radiometal coordination‐driven conformational interlocked network with ultra‐high radiostability. This platform enables low‐temperature, multi‐radionuclide labeling for SPECT/PET/MRI imaging and radionuclide therapy. Mechanistic insights from EXAFS and DFT reveal enhanced stability, while in
Xiao Xu   +10 more
wiley   +1 more source

Systematic Fluoroscopic-Echocardiographic Fusion Imaging Protocol for Transcatheter Edge-to-Edge Mitral Valve Repair Intraprocedural Monitoring.

open access: yes, 2022
DOI: 10.1016/j.echo.2021.01.010 Fluoroscopic-echocardiographic fusion imaging (FI) is able to acquire imaging data from both fluoroscopy and transesophageal images and co-register and align them in the 3D space and time by putting onto the same ...
Agricola, Eustachio
core   +1 more source

Implantable Systems for Cardiovascular Treatment and Monitoring: Comparative Insights From Intracardiovascular and Extracardiovascular Technologies

open access: yesAdvanced Intelligent Systems, EarlyView.
A unifying device–cardiovascular interface framework is presented to classify implantable cardiovascular technologies as intracardiovascular blood‐contacting systems or extracardiovascular tissue‐only and blood‐handling architectures. Cross‐class comparison across shared semiquantitative criteria, including blood‐contact burden, biomimicry ...
Bergo Nicolò   +7 more
wiley   +1 more source

Home - About - Disclaimer - Privacy