Results 61 to 70 of about 101,460,446 (165)
Transcatheter edge-to-edge repair in functional tricuspid regurgitation
Abstract Tricuspid edge-to-edge repair (T-TEER) has emerged as a promising treatment option for severe functional tricuspid regurgitation (TR) in patients unsuitable for surgery. Recent findings from randomized clinical trials consistently demonstrated a reduction in TR severity and significant symptomatic improvement with T-TEER ...
Bacigalupi, Elena +7 more
openaire +2 more sources
Background: Transcatheter edge-to-edge repair has emerged as a minimally invasive option for patients at high surgical risk. Residual/recurrent tricuspid regurgitation (TR) is associated with high morbidity and mortality.
Andreas Winkler, MD +6 more
doaj +1 more source
ABSTRACT Background Left atrial appendage occlusion (LAAO) has emerged as a non‐pharmacological alternative to oral anticoagulation (OAC) for stroke prevention in patients with atrial fibrillation (AF). Following the publication of recent CHAMPION‐AF and CLOSURE‐AF trials, an updated synthesis of evidence is warranted to clarify the long‐term ...
Ahmed Nazmy +11 more
wiley +1 more source
Transcatheter edge-to-edge repair in secondary mitral regurgitation
Secondary mitral regurgitation (SMR) is frequent among patients with heart failure (HF) with reduced ejection fraction (HFrEF), and it is strongly associated with increased mortality, frequent hospitalisations, and poor quality of life. The mechanisms underlying SMR are multifactorial.
Rodés-Cabau, Josep +4 more
openaire +3 more sources
ObjectiveWe aimed to compare the clinical outcomes of transcatheter edge-to-edge repair (TEER) and surgical repair in patients with non-rheumatic mitral regurgitation (MR) using real-world data.MethodsWe conducted a retrospective cohort study using ...
Kuan-Chieh Tu +2 more
doaj +1 more source
Dyssynchrony without dysfunction: Left bundle branch block does not acutely reduce cardiac output
Abstract figure legend Six electromechanical in silico heart models were simulated under healthy and pure acute left bundle branch block (LBBB) conditions. LBBB induced electrical dyssynchrony and increased left ventricular free wall strain, while the right and left ventricular ejection fraction remained relatively unchanged.
Carola Kruthoff +6 more
wiley +1 more source
Residual and recurrent tricuspid regurgitation may occur frequently after surgical tricuspid valve repair. However, reoperation for tricuspid regurgitation is rare, although many patients are again highly symptomatic. Tricuspid transcatheter edge-to-edge
Jafer Haschemi (14023287) +4 more
core +1 more source
Residual and recurrent tricuspid regurgitation may occur frequently after surgical tricuspid valve repair. However, reoperation for tricuspid regurgitation is rare, although many patients are again highly symptomatic. Tricuspid transcatheter edge-to-edge
Jafer Haschemi (14023287) +4 more
core +1 more source
Successful Percutaneous Retrieval of an Embolized MitraClip From the Right Subclavian Artery
ABSTRACT Single leaflet device attachment (SLDA) after mitral transcatheter valve edge‐to‐edge repair (M‐TEER) has been reported in up to 5% of patients. However, complete embolization of the M‐TEER device is exceedingly rare. Device retrievals in all previously reported cases were completed by vascular surgery cut down at the end. In this case, we are
Seyed Hossein Aalaei‐Andabili +2 more
wiley +1 more source
Background Systemic inflammatory response syndrome (SIRS) following cardiovascular interventions is associated with adverse events during hospitalization and follow‐up.
Carlo Mannina +12 more
doaj +1 more source

