Results 21 to 30 of about 608,521 (211)
Transcatheter Mitral Valve-in-Valve Implantations Using Inverted J-Valve
BackgroundAs bioprosthetic valves are being widely used, the incidence of structural valve deterioration increases, as well as the need for reoperation. Transcatheter mitral valve-in-valve implantations are being increasingly adopted as an alternative to
Lulu Liu +3 more
doaj +1 more source
Failed valve-in-valve transcatheter mitral valve implantation [PDF]
A 73-year old man underwent trans-septal anterograde implantation of a 26-mm Sapien-XT valve (Edwards Lifesciences, CA, USA) to treat a degenerated 27-mm Carpentier-Edwards bioprosthesis. During the follow-up, the patient experienced severe haemolysis with moderate-to-severe inter-valvular leak, and fluoroscopy revealed possible incomplete apposition ...
Bruschi, G. +3 more
openaire +3 more sources
New Self-Expanding Transcatheter Valve for Off-Pump Transatrial Mitral Valve-In-Ring Implantation. [PDF]
OBJECTIVES To validate a self-expanding transcatheter valve for off-pump transatrial mitral valve-in-ring (VIR) implantation via a left thoracotomy. METHODS Mitral valve annuloplasty was performed via sternotomy during cardiopulmonary bypass on ...
Yu, Zipu +6 more
core +3 more sources
The transcatheter mitral valve prosthesis is ideally suited for patients with inoperable mitral etiology. The transcatheter mitral valve implantation (TMVI) procedure has closely followed the evolution of transcatheter aortic procedures.
Faizus Sazzad +20 more
doaj +1 more source
Transapical Transcatheter Mitral Valve Implantation with the Tendyne Valve: The Swiss Experience
BACKGROUND The aim of this study was to report outcomes of all patients undergoing transcatheter mitral valve implantation with the Tendyne Mitral Valve System (Tendyne) in Switzerland.
David Reineke +15 more
core +1 more source
Transcatheter Aortic Valve Implantation in Dialysis Patients [PDF]
Background/Aims: Transcatheter aortic valve implantation (TAVI) has emerged as a new therapeutic option for high-risk patients. However, dialysis patients were excluded from all previous studies.
Wessely, Matthias +6 more
core +1 more source
Assessment of mitral regurgitation and mitral complex geometry in patients after transcatheter aortic valve implantation [PDF]
Introduction: Mitral regurgitation (MR) of varying degrees and mechanisms is a common finding in patients with aortic stenosis with different improvement after transcatheter aortic valve implantation (TAVI).
Dziewierz, Artur +19 more
core +1 more source
Valve-in-valve implantation for dysfunctional bioprosthetic valves has been shown to be a safe and feasible option for selected patients (Dvir et al., 2014, Bapat et al., 2012, Piazza et al., 2011).
A.B. Gopalamurugan +4 more
doaj +1 more source
Local versus general anesthesia for transcatheter aortic valve implantation (TAVR)- systematic review and meta-analysis [PDF]
The hypothesis of this study was that local anesthesia with monitored anesthesia care (MAC) is not harmful in comparison to general anesthesia (GA) for patients undergoing Transcatheter Aortic Valve Implantation (TAVR).TAVR is a rapidly spreading ...
Webb, J +32 more
core +2 more sources
Leadless pacemakers provide a potential alternative to conventional transvenous pacemakers for patients undergoing high-risk transcatheter valve replacement procedures.
Enes Elvin Gul +4 more
doaj +1 more source

