Results 21 to 30 of about 6,001 (168)

Control optimisatlion of CO(2) cycles for medium temperature retail food refrigeration systems [PDF]

open access: yes, 2009
This is the post-print version of the final paper published in International Journal of Refrigeration. The published article is available from the link below.
Ge, YT, Tassou, SA
core   +1 more source

Performance evaluation and optimal design of supermarket refrigeration systems with supermarket model "SuperSim", Part II: Model applications [PDF]

open access: yes, 2011
This is the post-print version of the final paper published in International Journal of Refrigeration. The published article is available from the link below.
Y.T. Ge, S.A. Tassou, Ge, YT, Tassou, SA
core   +1 more source

TRANSCRITICAL FLOW PAST AN OBSTACLE [PDF]

open access: yesThe ANZIAM Journal, 2010
AbstractIt is well known that transcritical flow past an obstacle may generate undular bores propagating away from the obstacle. This flow has been successfully modelled in the framework of the forced Korteweg–de Vries equation, where numerical simulations and asymptotic analyses have shown that the unsteady undular bores are connected by a locally ...
openaire   +1 more source

Performance evaluation of transcritical CO2 desiccant heat pumps for electric vehicles [PDF]

open access: yes, 2023
Transcritical CO2 heat pump systems are eco-friendly and have excellent heating performance, which makes them suitable for electric vehicles. The recirculation mode can save energy but requires a dehumidification function to ensure driving safety ...
Valdiserri P.   +4 more
core   +1 more source

Transcritical riddling in a system of coupled maps [PDF]

open access: yesPhysical Review E, 2001
The transition from fully synchronized behavior to two-cluster dynamics is investigated for a system of N globally coupled chaotic oscillators by means of a model of two coupled logistic maps. An uneven distribution of oscillators between the two clusters causes an asymmetry to arise in the coupling of the model system.
Popovych, Orest   +4 more
openaire   +4 more sources

Energy Optimization for Transcritical CO2 Heat Pumps for Combined Heating and Cooling and Thermal Storage Applications [PDF]

open access: yes, 2012
A transcritical heat pump (THP) cycle using carbon dioxide (CO2) as the refrigerant is known to feature an excellent coefficient of performance (COP) as a thermodynamic system.
Yazawa, Kazuaki   +3 more
core   +1 more source

Development of Performance Test Facility of Positive Displacement CO2 Refrigerant Compressor [PDF]

open access: yes, 2012
Due to the transcritical nature, some of the test methods used in the conventional subcritical refrigeration cycle, such as the liquid refrigerant flow metering method and the water-cooled condenser metering method, are no longer appropriate for ...
Wang, Rujin   +4 more
core   +1 more source

On “transcritical” and “hypercritical” flows in magnetogasdynamics [PDF]

open access: yesQuarterly of Applied Mathematics, 1961
The existence of smooth flows in transonic, transAlfvenic, and hypercritical regimes is determined. The flow behavior in the hypercritical regime is, in general, regular for the case gamma =2. Phenomena associated with the flow of a highly conducting gas in the presence of a strong aligned magnetic field are exemplified in two simple solutions. (L.N.N.)
openaire   +1 more source

Detailed Theoretical Characterization of a Transcritical CO2 Direct Expansion Ground Source Heat Pump Water Heater

open access: yesEnergies, 2018
A new avenue in modern heat pump technology is related to the use of natural refrigerants such as carbon dioxide (CO2). The use of CO2 in direct expansion ground source heat pumps (DX-GSHP) has also gained significant interest as it offers opportunities ...
Parham Eslami-Nejad   +3 more
doaj   +1 more source

Thermodynamic Analysis of a Modified Two-Stage Trans-Critical CO2 Refrigeration Cycle with Multi Inter-Cooling System [PDF]

open access: yesInternational Journal of Advanced Design and Manufacturing Technology, 2017
Performance of a two-stage multi-inter-cooling trans-critical CO2 refrigeration cycle containing internal heat exchanger, two intercoolers, ejector, and separator, has been analyzed after modification. In the present study, an internal heat exchanger has
Ahmad Reza Rahmati, Ali Gheibi
doaj  

Home - About - Disclaimer - Privacy