Results 161 to 170 of about 2,214,703 (207)
Optimisation of cycle and turbine designs for transcritical cycles of CO2-based working fluids
openaire +1 more source
Experimental Verification of the Self-Condensing CO2 Transcritical Power Cycle
CO2 is an excellent natural working fluid for both power cycles and refrigeration cycles. However, it limits the actual application of the CO2 transcritical power cycle that subcritical CO2 is hard to be condensed by conventional cooling water. Aiming to
Lisheng Pan, Weixiu Shi, Xiaolin Wei
exaly +3 more sources
Optimization of the Self-Condensing CO2 Transcritical Power Cycle Using Solar Thermal Energy
Compared with the conventional Rankine cycle, the CO2 transcritical power cycle gives a higher thermal efficiency because of its high average heat absorbing temperature and is suitable for driving a compact system.
Lisheng Pan, Weixiu Shi, Xiaolin Wei
exaly +3 more sources
Transcritical CO2 Refrigeration Cycle With Ejector-Expansion Device
An ejector expansion transcritical CO2 refrigeration cycle is proposed to improve the COP of the basic transcritical CO2 cycle by reducing the expansion process losses. A constant pressure mixing model for the ejector was established to perform the thermodynamic analysis of the ejector expansion transcritical CO2 cycle.
Eckhard Groll, Daqing Li
exaly +3 more sources
Some of the next articles are maybe not open access.
Related searches:
Related searches:
Nonlinear adaptive control of a transcritical Organic Rankine Cycle
2017 IEEE 26th International Symposium on Industrial Electronics (ISIE), 2017This paper presents an adaptive control design for a transcritical Organic Rankine Cycle (TORC) working in both supercritical and subcritical regions. Even though supercritical operation increases the overall efficiency, previous research has focused on developing controls for ORCs working in the subcritical region only.
Jilan Samiuddin +4 more
openaire +2 more sources
CO2 Transcritical Cycle for Ground Source Heat Pump
2009 WRI World Congress on Computer Science and Information Engineering, 2009This paper gave a schematic of the CO2 transcritical cycle for ground source heat pump system and compared it with the cycles of R22 and R134a.The volumetric efficiency and isentropic efficiency is also taken into consideration in this comparison.
Jinggang Wang, Ligai Kang, Jie Liu
openaire +2 more sources
CO2 Transcritical Cycles for High Temperature Applications
Advanced Energy Systems, 2001Abstract A breadboard CO2 prototype heat pump for stationary applications was designed, constructed, and tested. Test results of the CO2 prototype showed about 12% lower cooling capacity but a similar cooling Coefficient of Performance (COP) at 40°C (104°F) ambient temperature as compared to R-22 environmental control units (ECU ...
Yunho Hwang +3 more
openaire +1 more source
Thermodynamic Analysis of Transcritical Carbon Dioxide Cycles
Advanced Energy Systems, 2005Research on natural environmentally friendly refrigerants is very important especially because the world-wide agreement about restriction in the use of ozone depleting refrigerants. Carbon dioxide is a natural refrigerant that has been considered for certain refrigeration and air conditioning applications.
Mark Brown +2 more
openaire +1 more source
Performance Analysis of Transcritical CO2 Compression Cycle
2012With the growing awareness of dual threats of global warming and ozone depletion, environmentally benign natural refrigerants have attracted considerable attention. As a natural refrigerant, CO2 is a potential substitute for synthesized refrigerants with favorable environmental properties.
Hongli Wang, Jingrui Tian, Huiqin Liu
openaire +1 more source
Energy, 2011
Abstract In this paper, two new CO 2 cascade refrigeration cycles are proposed and analyzed. In both these cycles the top cycle is an ejector-expansion transcritical cycle and the bottom cycle is a sub-critical CO 2 cycle. In one of these proposed cycles the waste heat from the gas cooler is utilized to drive a supercritical CO 2 power cycle ...
Mortaza Yari, S.M.S Mahmoudi
openaire +1 more source
Abstract In this paper, two new CO 2 cascade refrigeration cycles are proposed and analyzed. In both these cycles the top cycle is an ejector-expansion transcritical cycle and the bottom cycle is a sub-critical CO 2 cycle. In one of these proposed cycles the waste heat from the gas cooler is utilized to drive a supercritical CO 2 power cycle ...
Mortaza Yari, S.M.S Mahmoudi
openaire +1 more source