Results 161 to 170 of about 256,745 (264)
The conductive and stretchable photothermal CuSe fiber is fabricated for versatile biomedical applications. This CuSe fiber functions as a reliable wearable strain sensor and heater due to its high conductivity, stretchability and photothermal efficiency.
Kukro Yoon +9 more
wiley +1 more source
A monolayer graphene/phosphoric‐acid mixed proton‐electron conducting membrane combines proton‐conducting nanoconfined acid channels with electron‐conducting graphene nanosheets for efficient high‐temperature hydrogen purification. The membrane achieves nearly 100% H2/CO2 selectivity and 69 GPU hydrogen permeance at 250°C, arising from synergistic ...
Kaiqiang He +8 more
wiley +1 more source
Effect of HIFU frequency on gold removal efficiency from e-waste. [PDF]
Pudas T +10 more
europepmc +1 more source
Bioprinting Organs—Science or Fiction?—A Review From Students to Students
Bioprinting artificial organs has the potential to revolutionize the medical field. This is a comprehensive review of the bioprinting workflow delving into the latest advancements in bioinks, materials and bioprinting techniques, exploring the critical stages of tissue maturation and functionality.
Nicoletta Murenu +18 more
wiley +1 more source
In vivo acoustoelectric neural recording in mice enabled by ultrasound-induced frequency mixing. [PDF]
Rintoul JL +4 more
europepmc +1 more source
Microfluidic Modeling of Macrophage‐Induced Cardiac Inflammation Using NF‐κB Reporter Cardiomyocytes
A cardiac inflammation model was developed to enable real‐time analysis of macrophage‐cardiomyocyte interactions using NF‐κB‐reporter cardiomyocytes and a microfluidic co‐culture system. A MATLAB‐based model was implemented to optimize cell density and medium resupply based on TNFα diffusion kinetics. Activation thresholds and stress responses in NF‐κB‐
Chao Liu +6 more
wiley +1 more source
Limits on transverse zero sound in Fermi liquid <sup>3</sup>He. [PDF]
Nguyen MD +4 more
europepmc +1 more source
An Edible H2O2 Biosensor for Gastrointestinal Metabolites and Peroxidase Enzyme Quantification
We present an edible biosensor for gastric fluid analysis that integrates a caffeic acid–horseradish peroxidase redox system into an edible electrolyte‐gated transistor. The device enables rapid, low‐volume detection of H2O2 and, with minimal modification, metabolites and enzyme activity in simulated gastrointestinal conditions.
Valerio Francesco Annese +10 more
wiley +1 more source
Same Session Validation of a Custom-Built 22G With the Commercial 25G System for EUS-Guided Portal Pressure Gradient Measurement. [PDF]
Praktiknjo M +12 more
europepmc +1 more source

