In this paper, the authors have developed a hardware model for blocking even and odd harmonics of a power transformer. In the proposed hardware model, intelligent differential & over-current relays are used for the blocking of harmonics of a power ...
Abdul Azeem +4 more
doaj +1 more source
The low voltage ride-through (LVRT) requirements demand large-scale photovoltaic (PV) power generation system remain connected to the grid during faults. It results in considerable impact on the characteristics of fault current.
Guosheng Yang +5 more
doaj +1 more source
New Hybrid Machine Learning Method for Detecting Faults in Three-Phase Power Transformers
A novel hybrid machine learning technique is proposed for the protection of three-phase power transformers in this study. Here, the developed model was tested across several types of current signal fault cases from different fault conditions and examined
Othman Abdusalam +3 more
doaj +1 more source
The algorithms of the present generation of practical differential relays are based on two methods. The first method is based on the ratio of the harmonic content of the differential current, and the second one is based on the length of the time interval
Ali Sahebi +4 more
doaj +1 more source
Protection of transformers, as one of the most expensive equipment in the power system, against lightning overvoltage impulses is a vital task. This paper, for the first time so far, investigates the effects of a filtered spark gap on the protection ...
Mahdi Pourakbari-Kasmaei +6 more
doaj +1 more source
Primary Current Test Method for Transformer Protection Based on Transient Load
When test load is insufficient, the current transformer (TA) secondary circuit test by primary current cannot be completed, which often results in the failure of new transformer protection to be put into normal operation.
Jiyin SHI
doaj +1 more source
In order to increase the transmission capacity of the new energy grid-connected transformer,a two-voltage three-winding transformer with star-angle-angle connection form is adopted.
XING Wu +3 more
doaj +1 more source
Since the fault current output from the doubly-fed wind farm has frequency deviation characteristics and contains large harmonic components, when an internal fault occurs in the transmission transformer for the doubly-fed wind farm, the ratio of the ...
Yanchun XU +3 more
doaj +1 more source
Transformer Monitoring and Protection in Dynamic Power Systems – A Review
Increasing distributed energy resources, especially the renewable energy resources (RESs) are being installed across power systems these years. These RESs, including solar photovoltaic, wind turbines, etc., provide opportunities for operators to improve ...
Boqi Xie, Dongbo Zhao, Tianqi Hong
doaj +1 more source
This paper proposes an algorithm for fault detection, faulted phase and winding identification of a three-winding power transformer based on the induced voltages in the electrical power system.
Byung Eun Lee +3 more
doaj +1 more source