Application of operational modal analysis to investigate transformer vibration patterns
This paper develops an operational modal analysis application framework for vibration measurement‐based condition monitoring of transformer winding structure.
Jakob Pallot +3 more
doaj +1 more source
In order to analyze the transient magnetic field and transient electrodynamic characteristics of transformer windings under shorL-circuit impact, according to the Lheo1-y of leakage magnetic field of transformer windings and the principle of calculation ...
MU Long +5 more
doaj +1 more source
Study on the Method of Calculating Temperature Rise of Transformer [PDF]
The internal temperature of the transformer is a key parameter to measure the thermal state of the transformer. The service life of the transformer generally depends on the life of the insulating material, and high temperature is the main reason why ...
Li Tao +3 more
doaj +1 more source
Transformer design difficulties of current resonant converter for high power density and wide input voltage range [PDF]
A current resonant converter including wider input voltage range and higher power density is required for various applications. However, in our study, it has been found that the drastic increasing of the transformer winding loss becomes a severe problem.
Abe Seiya, Zaitsu Toshiyuki
core +2 more sources
Achieving the desired transformer leakage inductance necessary in DC-DC converters for energy storage applications [PDF]
This paper presents a cost effective winding design and evaluation of a medium frequency isolation transformer typically used in bidirectional isolated DC/DC converters.
Asher, Greg +5 more
core +1 more source
MACHINE-TRANSFORMER UNITS FOR WIND TURBINES
Background. Electric generators of wind turbines must meet the following requirements: they must be multi-pole; to have a minimum size and weight; to be non-contact, but controlled; to ensure the maximum possible output voltage when working on the power supply system. Multipole and contactless are relatively simply realized in the synchronous generator
V.I. PANCHENKO +4 more
openaire +5 more sources
Evaluation Method for Winding Performance of Distribution Transformer
In order to ensure the safe and stable operation of a power system, the performance evaluation of transformer windings after a short-circuit test can predict whether the windings are deformed in order to provide a useful reference for the operation and ...
Chunguang Suo +5 more
doaj +1 more source
The insulation co-ordination of converter transformer winding has a great influence on power system security. An equivalent circuit of a 500 kV converter transformer winding structure, including a LC equivalent network circuit and an ideal transformer in
Hongrui Jia +4 more
doaj +1 more source
Controlling the highest temperature in the windings is the primary objective of transformer thermal design to guarantee designed transformer thermal life expectancy.
Xiang Zhang +3 more
doaj +1 more source
Fault diagnostics in power transformer model winding for different alpha values
Transient overvoltages appearing at line terminal of power transformer HV windings can cause failure of winding insulation. The failure can be from winding to ground or between turns or sections of winding.