Turn-to-turn fault protection technique for synchronous machines without additional voltage transformers [PDF]

open access: yes, 2017
This paper presents a novel protection technique for the detection of inter-turn faults in synchronous machines. It is based on the calculation of voltage in the stator windings from the usual phases and neutral voltage, typically available in ...
Gyftakis, Konstantinos N.   +2 more
core   +1 more source

Structural biology of ferritin nanocages

open access: yesFEBS Letters, EarlyView.
Ferritin is a conserved iron‐storage protein that sequesters iron as a ferric mineral core within a nanocage, protecting cells from oxidative damage and maintaining iron homeostasis. This review discusses ferritin biology, structure, and function, and highlights recent cryo‐EM studies revealing mechanisms of ferritinophagy, cellular iron uptake, and ...
Eloise Mastrangelo, Flavio Di Pisa
wiley   +1 more source

Novel Transformer Fault Identification Optimization Method Based on Mathematical Statistics

open access: yesMathematics, 2019
Most power transformer faults are caused by iron core and winding faults. At present, the method that is most widely used for transformer iron core and winding faults identification is the vibration analysis method.
Zhanlong Zhang   +6 more
doaj   +1 more source

Flat-band assembly for toroidal transformer cores [PDF]

open access: yes, 1973
Toroidal transformer cores are often banded together by means of strap. Spot welds secure strap. Proper tension is obtained by use of special fixture in conjunction with winding of wire which is placed temporarily on core; winding is excited by dc ...
Mclyman, W. T.
core   +1 more source

Research on Transformer Winding Deformation and Winding Resistance

open access: yesDEStech Transactions on Environment, Energy and Earth Science, 2016
In this paper, the influence of transformer winding deformation on the equivalent electrical parameters is studied, and the proximity effect and skin effect caused by AC current in the wire are simulated. It is verified that the current distribution will be affected by the proximity effect and skin effect.
Chen Ling   +3 more
openaire   +2 more sources

A methionine‐lined active site governs carbocation stabilization and product specificity in a bacterial terpene synthase

open access: yesFEBS Letters, EarlyView.
This study reveals a unique active site enriched in methionine residues and demonstrates that these residues play a critical role by stabilizing carbocation intermediates through novel sulfur–cation interactions. Structure‐guided mutagenesis further revealed variants with significantly altered product profiles, enhancing pseudopterosin formation. These
Marion Ringel   +13 more
wiley   +1 more source

Detection of inter turn fault in transformer windings by parameters of their transition processes

open access: yesИзвестия высших учебных заведений: Проблемы энергетики, 2019
The proposed method of detection the inter turn fault of transformer windings relates to the area of defectoscopy and allows detecting inter turn faults in a wide range of damaged (closed) turns.
R. G. Mustafin
doaj   +1 more source

Leveraging Sensory Data in Estimating Transformer Lifetime

open access: yes, 2017
Transformer lifetime assessments plays a vital role in reliable operation of power systems. In this paper, leveraging sensory data, an approach in estimating transformer lifetime is presented.
Hosseini, Zohreh S.   +3 more
core   +1 more source

Valosin‐containing protein counteracts ATP‐driven dissolution of FUS condensates through its ATPase activity in vitro

open access: yesFEBS Letters, EarlyView.
Biomolecular condensates formed by fused in sarcoma (FUS) are dissolved by high ATP concentrations yet persist in cells. Using a reconstituted system, we demonstrate that valosin‐containing protein (VCP), an AAA+ ATPase, counteracts ATP‐driven dissolution of FUS condensates through its D2 ATPase activity.
Hitomi Kimura   +2 more
wiley   +1 more source

Influence of the Parameters of Disk Winding on the Impulse Voltage Distribution in Power Transformers

open access: yesIranian Journal of Electrical and Electronic Engineering, 2014
Overvoltage distribution along the transformer winding must be uniform to certify the safety of the operation of the power transformer. Influence of the parameters variation on the impulse voltage distribution (IVD) in disk winding transformer is going ...
M. Heidarzadeh, M. R. Besmi
doaj  