Results 61 to 70 of about 37,003 (356)
Evaluation of Lightning Impulse Test by Frequency Response Analysis [PDF]
In this work are presented the basis for improving the interpretation of transformer lightning impulse test and the development of a graphical user interface system, which allows comparisons of time domain data and frequency response.
Ramírez, Jorge, Valecillos, Baudilio
core +3 more sources
LDAcoop: Integrating non‐linear population dynamics into the analysis of clonogenic growth in vitro
Limiting dilution assays (LDAs) quantify clonogenic growth by seeding serial dilutions of cells and scoring wells for colony formation. The fraction of negative wells is plotted against cells seeded and analyzed using the non‐linear modeling of LDAcoop.
Nikko Brix +13 more
wiley +1 more source
Real Time Measurement of Average Winding Resistances of Transformers
The monitoring of transformers that are expensive equipment of power systems is the one of important issues. Transformer monitoring systems are usually used in order to detect failures, to determine the lifetime, to measure losses and to monitor winding
Cenk GEZEGİN +2 more
doaj +1 more source
A novel energy router based on multi‐winding line frequency transformer
Energy routers based on the electronic power transformer are suitable for the AC–DC hybrid grid with multiple voltage levels, but their structures are complex.
Zhitao Guan +4 more
doaj +1 more source
Power supply with automatic power factor conversion ...
Kramer, M., Martinage, L. H.
core +1 more source
Nanosecond infrared laser (NIRL) low‐volume sampling combined with shotgun lipidomics uncovers distinct lipidome alterations in oropharyngeal squamous cell carcinoma (OPSCC) of the palatine tonsil. Several lipid species consistently differentiate tumor from healthy tissue, highlighting their potential as diagnostic markers.
Leonard Kerkhoff +11 more
wiley +1 more source
Methodology to locate and quantify radial winding deformation in power transformers
Frequency response analysis (FRA) is a tool that can be used to detect changes within the structural geometry of a transformer. One application of FRA is to detect winding displacement after the transformer experiences an overcurrent event.
Steven D. Mitchell, James S. Welsh
doaj +1 more source
Adjustment of model parameters to estimate distribution transformers remaining lifespan [PDF]
Currently, the electrical system in Argentina is working at its maximum capacity, decreasing the margin between the installed power and demanded consumption, and drastically reducing the service life of transformer substations due to overload (since the ...
Gotay Sardiñas, Jorge +3 more
core +1 more source
We show that the majority of the 18 analyzed recurrent cancer‐associated ERBB4 mutations are transforming. The most potent mutations are activating, co‐operate with other ERBB receptors, and are sensitive to pan‐ERBB inhibitors. Activating ERBB4 mutations also promote therapy resistance in EGFR‐mutant lung cancer.
Veera K. Ojala +15 more
wiley +1 more source
With the increasing demand for the resilient capacity of transformers in high-proportion renewable energy grids, the overload capacity of transformers and the thermal conductivity of winding insulation materials have been put forward as important ...
Haomin Li +4 more
doaj +1 more source

