Electromagnetic-force calculation and fault diagnosis of shell transformer under inter-turn short circuit [PDF]
Aiming at the electromagnetic distribution law, winding mechanical response characteristics, and degree diagnosis of inter-turn short circuit fault locations of shell-type transformers under inter-turn short circuits, the research idea of “simulation ...
Duanjiao Li +5 more
doaj +1 more source
Partial Discharge Location within a Transformer Winding using Principal Component Analysis
Partial discharge (PD) may occur in a transformer winding due to ageing processes, operational over stressing or defects introduced during manufacture. The presence of PD does not necessarily indicate imminent failure of the transformer but it will lead ...
Abd Rahman, M S, Hao, L, Lewin, P L
core
High voltage pulse generator Patent [PDF]
High voltage pulse generator for testing flash and ignition limits of nonmetallic materials in controlled ...
Pippen, D. L.
core +1 more source
Basroparib inhibits YAP‐driven cancers by stabilizing angiomotin
Basroparib, a selective tankyrase inhibitor, suppresses Wnt signaling and attenuates YAP‐driven oncogenic programs by stabilizing angiomotin. It promotes AMOT–YAP complex formation, enforces cytoplasmic YAP sequestration, inhibits YAP/TEAD transcription, and sensitizes YAP‐active cancers, including KRAS‐mutant colorectal cancer, to MEK inhibition.
Young‐Ju Kwon +4 more
wiley +1 more source
Methods for determining the scattering of transformer windings individually
The total leakage reactance of the transformer with concentric cylindrical windings depends on the thickness of the coils and the gap between them.
Popov I. P.
doaj +1 more source
Location of Partial Discharges within a Transformer Winding Using Principal Component Analysis
Partial discharge (PD) may occur in a transformer winding due to ageing processes or defects introduced during manufacture. A partial discharge is defined as a localised electric discharge that only partially bridges the dielectric insulator between ...
Abd Rahman, M S, Hao, L, Lewin, P L
core
This work identified serum proteins associated with pancreatic epithelial neoplasms (PanINs) and early‐stage PDAC. Proteomics screens assessed genetically engineered mice with abundant PanINs, KPC mice (Lox‐STOP‐Lox‐KrasG12D/+ Lox‐STOP‐Lox‐Trp53R172H/+ Pdx1‐Cre) before PDAC development and also early‐stage PDAC patients (n = 31), compared to benign ...
Hannah Mearns +10 more
wiley +1 more source
The insulation degradation of a voltage transformer winding is not easy to find, but it may ultimately cause the transformer to explode, leading to accidents such as phase-to-phase short circuits.
Hongwen Liu +4 more
doaj +1 more source
Power transformers are one of the most important devices in electrical networks. The safety operation of the transformers directly affects the reliability of the power system. To diagnose the internal deformation of the transformer as soon as possible is
Song Wang +6 more
doaj +1 more source