Condition monitoring of the power transformer winding and diagnose of the fault in its incipient stages can prevent the spread of defect, and as a result, the unexpected exit of the transformer.
Hadi Tarimoradi, Milad Askari
doaj +1 more source
Research on Transformer Winding Deformation and Winding Resistance
In this paper, the influence of transformer winding deformation on the equivalent electrical parameters is studied, and the proximity effect and skin effect caused by AC current in the wire are simulated. It is verified that the current distribution will be affected by the proximity effect and skin effect.
Chen Ling +3 more
openaire +2 more sources
SFRA, Detect of Winding Deformation in Power Transformer
The sweep frequency response analysis is extensively used technique for detect hidden fault and condition monitoring of power transformer. The operation is administered by supply a coffee voltage signal of varying frequencies to the transformer windings and measuring both the input and output signals.
Dr. B. Gopinath* +4 more
openaire +1 more source
When an electromagnetic transient occurs in a transformer, certain parts of the winding will be over stressed internally, which in severe cases will lead to the destruction of the winding insulation.
Chenchen Zhang +3 more
doaj +1 more source
Evaluation of Lightning Impulse Test by Frequency Response Analysis [PDF]
In this work are presented the basis for improving the interpretation of transformer lightning impulse test and the development of a graphical user interface system, which allows comparisons of time domain data and frequency response.
RamÃrez, Jorge, Valecillos, Baudilio
core +3 more sources
Magnetostrictive deformation of a transformer: a comparison between calculation and measurement [PDF]
Magnetostriction, which refers to the deformation of the core material of transformers and electrical machines, is a main contributor to the total noise.
Dirckx, Joris +4 more
core +1 more source
Methodology to locate and quantify radial winding deformation in power transformers
Frequency response analysis (FRA) is a tool that can be used to detect changes within the structural geometry of a transformer. One application of FRA is to detect winding displacement after the transformer experiences an overcurrent event.
Steven D. Mitchell, James S. Welsh
doaj +1 more source
The existing research on the distribution characteristics of displacement and acceleration of the transformer axial vibration under short-circuit conditions is based on ignoring the damping parameters.
Shuguo Gao +3 more
doaj +1 more source
The temperature distribution and deformation of the transformer windings cannot be measured in a distributed manner by the traditional method and failure location cannot be performed.
Yunpeng Liu +7 more
doaj +1 more source
It is well-known that the deformation of transformer winding can produce detectable changes to the frequency response spectrum compared with a referenced past measurement.
Mehdi Bagheri +3 more
doaj +1 more source