Method for detecting system on power transformer winding deformation
2009 International Conference on Electrical Machines and Systems, 2009This paper presents a detecting system on power transformer winding deformation which can enhance the diagnostic accuracy to a large degree. The Impulse Frequency Response Analysis (IFRA) method is developed for generating frequency response analysis trace (FRA trace) and Support Vector Machine (SVM) algorithm is used for predicting the transformer ...
Shaohua Ma, He Ren
openaire +1 more source
Study of transformer winding deformation by frequency response analysis
2013 IEEE Power & Energy Society General Meeting, 2013This paper proposes a methodology to interpret frequency response measurements of a deformed transformer winding due to conductors tilt. To achieve that, geometrical parameters of a three phase prototype transformer is used to simulate the frequency response of one of the windings using the multi-conductor transmission line model.
M. F. M. Yousof +2 more
openaire +1 more source
Deformation Diagnostic Methods for Transformer Winding through System Identification
2019 International Conference on Data Science and Communication (IconDSC), 2019Transformers play a critical role in the power system. Dynamics of the power system changes if the transformers are out of service for scheduled and unscheduled maintenance work under contingency situations. Faults, overloading, and mechanical abnormalities causes the incipient and critical damages to the transformer.
R. Venkataswamy, K. Uma Rao, P. Meena
openaire +1 more source
Detecting transformer winding deformation fault types based on continuous wavelet transform
2016 IEEE International Conference on Mechatronics and Automation, 2016When online detecting transformer winding deformation with impulse frequency response analysis, the time domain characteristics of transient signal could not be depicted by conventional frequency response curves, and the limitations of Fast Fourier Transform could result in deletion of available information.
openaire +1 more source
Use of a Deformation Coefficient for Transformer Winding Diagnostics
International Journal of Emerging Electric Power Systems, 2008This paper presents a novel method for deformation diagnostics of transformer windings using terminal measurements. The shortcomings of existing practices in locating deformation and determining its extent are discussed. The logical steps involved in devising the new method are elaborated.
Prasad M Joshi, S V Kulkarni
openaire +1 more source
On-line monitoring of winding deformation of power transformer
Proceedings of 2001 International Symposium on Electrical Insulating Materials (ISEIM 2001). 2001 Asian Conference on Electrical Insulating Diagnosis (ACEID 2001). 33rd Symposium on Electrical and Electronic Insulating Materials and Applications in System, 2002The feasibility of estimating transformer winding deformation by measuring short-circuit reactance is expounded. Based on the theoretical research, the on-line measurement system for short-circuit reactance of a transformer is proposed. The study on a power transformer in actual operating condition shows that the on-line method is satisfactory for ...
D.K. Xu, J.H. Huang, Y.M. Li
openaire +1 more source
Insulation characteristics of deformed transformer winding under transient impulse
2017 IEEE Conference on Electrical Insulation and Dielectric Phenomenon (CEIDP), 2017Oil-impregnated paper (OIP) insulation is a widely used insulating material in power transformer, and the insulation structure is often subjected to repeated impulses. Conventional research mainly focuses on the electrical accumulative effect of repeated impulses on the insulation. However, based on our study, only the electrical accumulative effect of
Haifeng Ye +6 more
openaire +1 more source
Survey of Frequency Response Analysis on Winding Deformation of Transformers
2019 4th International Conference on Intelligent Green Building and Smart Grid (IGBSG), 2019As a core equipment in power system, power transformer plays a vital role in the stability of the power grid. It is necessary to quickly and accurately monitor the fault of the transformer. Frequency response method is an important method for fault diagnosis of transformers.
Zhenhua Li +5 more
openaire +1 more source
Fault location of transformer winding deformation using frequency response analysis
Proceedings of 2001 International Symposium on Electrical Insulating Materials (ISEIM 2001). 2001 Asian Conference on Electrical Insulating Diagnosis (ACEID 2001). 33rd Symposium on Electrical and Electronic Insulating Materials and Applications in System, 2002FRA (frequency response analysis) is the best effective method that can successfully detect transformer winding deformation. This paper tries to diagnose the fault by the winding's physical parameter changes. At frequencies lower than critical frequency, the transformer winding may be modeled as a lossless transmission line that the series capacitance ...
null Jin Zhijian +2 more
openaire +1 more source
Recognition of power transformer winding movement and deformation using FRA
COMPEL - The international journal for computation and mathematics in electrical and electronic engineering, 2007PurposeThe purpose of this paper is to present a frequency domain technique for the recognition and location of winding movements and mechanical deformations in power transformers. Both, axial and radial coil movements, as well as changes in clamp pressure will be studied.Design/methodology/approachThe developed algorithm is based on using a ...
Saied, Mohamed M., Al-shaher, Meshal A.