Results 41 to 50 of about 1,104,045 (310)

Transient vibration analysis of a completely free plate using modes obtained by Gorman's superposition method

open access: yes, 2010
This paper shows that the transient response of a plate undergoing flexural vibration can be calculated accurately and efficiently using the natural frequencies and modes obtained from the superposition method.
Ilanko, Sinniah, Yusuke, Mochida
core   +1 more source

Research on transient insulation numerical analysis method of circuit breaker in GIS under lightning impulse voltage

open access: yesThe Journal of Engineering, 2019
In order to reveal the process of insulation destruction of circuit breaker in GIS under lightning impulse voltage, a new method of transient insulation numerical analysis is described in this paper.
Wu Qi   +3 more
doaj   +1 more source

Deep Sequencing of FLT3‐ITD Enables Response Evaluation and Post‐Treatment Monitoring in Childhood AML: An Exploratory Study

open access: yesPediatric Blood &Cancer, EarlyView.
ABSTRACT Background An internal tandem duplication in the gene encoding Fms‐like tyrosine kinase 3 (FLT3‐ITD) is associated with high relapse risk and poor prognosis in acute myeloid leukemia (AML) and plays a crucial role in treatment decisions. Measurable residual disease (MRD) analysis of FLT3‐ITD during and after treatment has shown prognostic ...
Sofie Johansson Alm   +11 more
wiley   +1 more source

On minimizing maximum transient energy growth [PDF]

open access: yes, 2005
The problem of minimizing the maximum transient energy growth is considered. This problem has importance in some fluid flow control problems and other classes of non-linear systems.
Whidborne, James F.   +2 more
core  

Application of Transient Analysis Techniques to Fault Diagnosis in Low- and Medium-Power Synchronous Machines

open access: yesMachines, 2023
Fault diagnosis techniques applied to synchronous motors such as Permanent Magnet Synchronous Machines (PMSMs) and Synchronous Reluctance Machines (SynRMs) are scarcely addressed in the literature, in strong contrast to the attention paid to asynchronous
Angela Navarro-Navarro   +5 more
doaj   +1 more source

Emapalumab for Immune Effector Cell‐Associated Hemophagocytic Lymphohistiocytosis‐Like Syndrome Following CD19‐Directed CAR‐T in Two Patients With B‐ALL: Clinical and Biomarker Correlates

open access: yesPediatric Blood &Cancer, EarlyView.
ABSTRACT Immune effector cell‐associated hemophagocytic lymphohistiocytosis‐like syndrome (IEC‐HS) is a life‐threatening hyperinflammatory toxicity distinct from cytokine release syndrome (CRS) and neurotoxicity following chimeric antigen receptor T‐cell (CAR‐T) therapy. In a single‐institution retrospective cohort of pediatric and young adult patients
Thomas J. Galletta   +6 more
wiley   +1 more source

Modelling of transient gas-liquid flow and pigging in pipes [PDF]

open access: yes, 1999
More and more transient gas-liquid operations in pipes are being successfully applied in the oil and gas industry. Pigging in two-phase pipelines, to remove liquid accumulation or for cleaning purposes, is an important transient operation.
Lima, P. C. R.
core  

The Role of Hematopoietic Cell Transplantation in Ataxia‐Telangiectasia

open access: yesPediatric Blood &Cancer, EarlyView.
ABSTRACT Background Ataxia‐telangiectasia (A‐T) is a DNA repair disorder characterized by neurodegeneration, immunodeficiency, and cancer predisposition. Hematopoietic cell transplantation (HCT) is an established therapy in related disorders such as Fanconi anemia (FA) and Nijmegen breakage syndrome (NBS), but its role in A‐T is unclear.
Laila Alkhouli   +3 more
wiley   +1 more source

Adaptive Filters with Error Nonlinearities: Mean-Square Analysis and Optimum Design

open access: yesEURASIP Journal on Advances in Signal Processing, 2001
This paper develops a unified approach to the analysis and design of adaptive filters with error nonlinearities. In particular, the paper performs stability and steady-state analysis of this class of filters under weaker conditions than what is usually ...
Sayed Ali H, Al-Naffouri Tareq Y
doaj   +1 more source

Transient analysis of surge immunity test for intrinsically safe sensor

open access: yesGong-kuang zidonghua, 2018
For problem that it was difficult to achieve evaluation grade A due to a long time reverse gap in DC power port voltage of intrinsically safe sensor in positive surge immunity test, taking a typical mine-used intrinsically safe methane sensor as research
ZHANG Ziliang
doaj   +1 more source

Home - About - Disclaimer - Privacy