Results 31 to 40 of about 29,042,117 (290)
STABILITY AND TRANSIENT ANALYSIS OF THE EOCR
The dynamic characteristics of the EOCR plant are investigated at fuli power (40 Mw). The stability margins of the various internal feed-back loops of the system as well as of the overall system with and without automatic power and temperature controls are analyzed by frequency response techniques.
S Gossmann, K Moore, F Hyer
openaire +2 more sources
Transient stability analysis of wind-thermal bundled system based on virtual inertia control
In this study, the transient stability characteristics of the wind-thermal bundled system is discussed when the wind turbine adopts the additional control of virtual inertia.
Yao Shujun +4 more
doaj +1 more source
Stability Analysis of the LHC Cables for Transient Heat Depositions [PDF]
The commissioning and the exploitation of the LHC require a good knowledge of the stability margins of the superconducting magnets with respect to beam induced heat depositions. Previous studies showed that simple numerical models are suitable to carry out stability calculations of multi-strands cables, and highlighted the relevance of the heat ...
P.P. Granieri +7 more
openaire +2 more sources
Applying series braking resistors to improve the stability of low inertia synchronous generators [PDF]
Widely held concerns over the environmental impact of emissions from large fossil fuelled generating plants are serving to promote the connection of renewable or sustainable generation onto distribution networks.
Bright, C.G. +4 more
core +4 more sources
INTRODUCTION: Synchronous condensers (SCs) are installed near renewable energy stations to suppress transient overvoltage and enhance transmission capacity, but they increase SC transient power-angle instability risk post-fault.
Cheng Lü +5 more
doaj +1 more source
Transient Stability Analysis of a Distribution Network With Distributed Generators [PDF]
This letter describes the transient stability analysis of a 10-kV distribution network with wind generators, microturbines, and CHP plants. The network being modeled in Matlab/Simulink takes into account detailed dynamic models of the generators. Fault simulations at various locations are investigated. For the studied cases, the critical clearing times
Xyngi, I. (author) +3 more
openaire +3 more sources
ABSTRACT Instruction Tenapanor potentially affects fluid volume and blood pressure. This study explored its effects on these parameters in patients undergoing peritoneal dialysis (PD). Methods We conducted a single‐arm, prospective observational study that enrolled 10 patients on PD with hyperphosphatemia who were newly initiated on tenapanor.
Shun Yoshida +11 more
wiley +1 more source
This paper presents a quantitative assessment of the transient stability of grid-forming converters, considering current limitations, inertia, and damping effects.
Jinlei Chen +6 more
doaj +1 more source
Plasma membranes contain dynamic nanoscale domains that organize lipids and receptors. Because viruses operate at similar scales, this architecture shapes early infection steps, including attachment, receptor engagement, and entry. Using influenza A virus and HIV‐1 as examples, we highlight how receptor nanoclusters, multivalent glycan interactions ...
Jan Schlegel, Christian Sieben
wiley +1 more source
With the development of new energy, the integration of large-scale doubly-fed wind turbin units into the power systems have a great impact on the transient stability of the power grid.
CHEN Shuiyao +4 more
doaj +1 more source

