Results 91 to 100 of about 278,712 (252)
Inspired by skeletal muscles’ precision and endurance, CoilLCE integrates a self‐sensing liquid crystal elastomer/graphene artificial muscle with an embedded Joule‐heating copper coil, enabling closed‐loop multistage actuation with programmable intermediate states (strain accuracy of 2%), and antagonistic coordination (32% total strain). These features
Ziyun Zhang +9 more
wiley +1 more source
Coulomb-correlated multi-electron states in a transmission electron microscope beam [PDF]
Haindl Rudolf +6 more
doaj +1 more source
Two Filters for Acquiring the Profiles from Images Obtained from Weak-Light Background, Fluorescence Microscope, Transmission Electron Microscope, and Near-Infrared Camera. [PDF]
Huang Y, Yang R, Geng X, Li Z, Wu Y.
europepmc +1 more source
USe3 is introduced as an actinide van der Waals semiconductor that mirrors the quasi‐one‐dimensional physics of transition‐metal trichalcogenides. Polarization‐resolved Raman spectroscopy on exfoliated flakes maps strong in‐plane phonon anisotropy and strain‐tunable mode shifts.
Aljoscha Söll +17 more
wiley +1 more source
Classification for transmission electron microscope images from different amorphous states using persistent homology. [PDF]
Uesugi F, Ishii M.
europepmc +1 more source
Electron spin resonance spectroscopy in a transmission electron microscope
8 pages, 4 ...
Jaroš, Antonín +6 more
openaire +3 more sources
Melanin content directly controls fungal spore mechanical properties, with pigmented spores achieving rupture forces two orders of magnitude higher than hyaline spores. Environmental stress drives this quantity‐quality tradeoff; stressed species invest energy in melanin‐reinforced, mechanically superior thick‐walled, super‐hydrophobic spores, while ...
Atul Agrawal, Steven E. Naleway
wiley +1 more source
The Relevance of Building an Appropriate Environment around an Atomic Resolution Transmission Electron Microscope as Prerequisite for Reliable Quantitative Experiments: It Should Be Obvious, but It Is a Subtle Never-Ending Story! [PDF]
Taurino A, Carlino E.
europepmc +1 more source
A gas‐fed, zero‐gap, PEM CO2 electrolyzer is realized by incorporating PDDA+ ions onto the carbonaceous Co/N‐C electrocatalyst, with gaseous H2 and CO2 fed into the anode and cathode, respectively. Operating without an aqueous electrolyte, the system sustains a peak FECO of 65.1% at 100 mA cm−2. ABSTRACT Electrochemical carbon dioxide reduction (ECO2R)
Yuen Leong Chow +6 more
wiley +1 more source
Cell therapies typically rely on cold‐chain logistics and cryopreservation, limiting access and compromising cell quality. Here, a dual‐chamber device separates an oxygen‐supplying chamber from a hyaluronic acid cargo chamber, sustaining oxygen delivery for over 70 h and enabling ambient‐temperature shipment.
Daniel A. Domingo‐Lopez +9 more
wiley +1 more source

