Results 231 to 240 of about 119,144 (295)
Static and dynamic analyses of a transmission tower-line system using a simplified model
openaire +1 more source
Some of the next articles are maybe not open access.
Related searches:
Related searches:
Wind fragility assessment and sensitivity analysis for a transmission tower-line system
Journal of Wind Engineering and Industrial Aerodynamics, 2022Jia Wang +4 more
semanticscholar +4 more sources
At present, the effect of tower-line coupling is neglected in seismic vibration control with TMD for transmission tower-line system. However, for large crossing transmission tower-line system(LCTL), the neglect can affect the performance of TMD. In this study, a typical FEM model of LCTL is established.
Gang Wu, Chang Hai Zhai, Shuang Li
openaire +2 more sources
Galloping of Transmission Tower-Line System and Anti-Galloping Research
A nonlinear finite element model of transmission tower-line coupling system including transmissions, towers and insulators is established based on ANSYS in this paper. The restarting technology is proposed to solve the vertical, horizontal and torsional galloping of the transmission conductors.
Li Li, Wei Jiang, Hua Jin Cao
openaire +2 more sources
Strain Rate Effect on Transmission Tower-Line System under Earthquake
Using ABAQUS software, three dimensional finite element model of a transmission tower-line system is created. Nonlinear seismic responses under three seismic records with and without strain rate effect are studied. The results show that the strain rate effect on the transmission tower-line system is more obvious with an increase in intensity of the ...
Wen Ming Wang +3 more
openaire +2 more sources
Journal of Aerospace Engineering, 2021
Because transmission tower-line systems are always exposed to the natural environment, such structures are vulnerable to various meteorological conditions, and the rupture of a transmission...
L. Tian, Kai Liu
semanticscholar +3 more sources
Because transmission tower-line systems are always exposed to the natural environment, such structures are vulnerable to various meteorological conditions, and the rupture of a transmission...
L. Tian, Kai Liu
semanticscholar +3 more sources
DYNAMIC RESPONSES OF TRANSMISSION TOWER-LINE SYSTEM UNDER ICE SHEDDING
Ice shedding from conductors may easily induce electrical and mechanical accidents, which cause a serious threat to the safe operation of transmission lines. In this paper, a 3D finite element model of tower-conductor-ground wire-insulator system was established in ANSYS, and the dynamic responses of ice shedding under different cases were analyzed ...
FENGLI YANG +3 more
openaire +2 more sources
Dynamic Response of Conductor Breakage for Oxytropis Transmission Tower-Line System
Dynamic response of conductor breakage is analyzed on guyed oxytropis transmission tower-line system of 500KV 5291 JinJiang-Zhenjiang lines. Considering unbalanced tension, finite element method is presented. Result of the transient analysis shows that the vibration of tower-line system happens after conductor breakage.
Ran Li, Qiang Gao
openaire +2 more sources
Dynamic Behavior of Transmission Tower-Line Systems Subjected to Insulator Breakage
Ice loads attached to a transmission tower-line system can not only increase the vertical loads on the insulators, but also cause flashover to occur more easily. Both effects can lead to an increased probability of insulator breakage. In this paper, a finite-element model of a transmission tower-line system with three towers and four span lines under ...
Jia-Xiang Li, Hong-Nan Li, Xing Fu
openaire +2 more sources

