Results 21 to 30 of about 119,144 (295)

Optimization of VEDs for Vibration Control of Transmission Line Tower

open access: yesAdvances in Civil Engineering, 2021
This paper investigates the optimization of viscoelastic dampers (VEDs) for vibration control of a transmission line tower. Considering the stiffness of the steel brace connected to a VED, the mechanical model of the VED-brace system was established ...
Guoping Huang   +4 more
doaj   +2 more sources

Wind induced coupling effects of transmission tower-line system at microtopography

open access: yesJournal of Physics: Conference Series, 2023
Abstract The coupled and uncoupled Dynamic Finite Element Models (DFEMs) of the transmission tower-line system consisting of two towers and three spans of conductors and ground wires were built at the windward and crosswind slope of a cosinoidal hill.
Weijun Zhong   +3 more
openaire   +2 more sources

Seismic responses of a long-span transmission tower and tower-line system

open access: yesJournal of Physics: Conference Series, 2022
The seismic responses of a long-span transmission tower (LTT) and tower-line system (TL) are presented in the paper. The mode decomposition response spectrum method (MDR) and time domain analysis method (TD) are both employed to obtain the seismic responses.
Guohui Shen   +4 more
openaire   +2 more sources

Investigation and Development of a Three-Dimensional Transmission Tower-Line System Model Using Nonlinear Truss and Elastic Catenary Elements for Wind Loading Dynamic Simulation

open access: yesShock and Vibration, 2021
The accuracy of transmission tower-line system simulation is highly impacted by the transmission line model and its coupling with the tower. Owing to the high geometry nonlinearity of the transmission line and the complexity of the wind loading, such ...
Xiao Zhu, Ge Ou
doaj   +2 more sources

De-icing Method for Coupled Transmission Tower-Line System

open access: yesEnergy Procedia, 2012
AbstractFor the disaster brought by the transmission line regelation, a new de-icing method is presented in this paper. It is supposed that the ice and transmission line are combined closely when there is no external loads, the composite structure of ice-transmission line is set up, then the coupled model of the composite structure-tower is set up. The
Cheng-Zhong, Qu, Yue-Jun, Liu
openaire   +2 more sources

Shaking Table Array Tests of an Ultra-High-Voltage Cup-Type Transmission Tower-Line System

open access: yesShock and Vibration, 2019
Ultra-high-voltage (UHV) cup-type transmission towers supported with long-span transmission lines are unavoidably subjected to the coupling action between the towers and the transmission lines. Therefore, investigating how tower-line coupling affects UHV
Fei Wang   +4 more
doaj   +2 more sources

Research on the Wind-induced Vibration Coefficient of Transmission Tower-line System

open access: yesPhysics Procedia, 2012
AbstractThe six different non-linear finite element model of the transmission tower-line system which have different spans and different height difference was established by the finite element analysis software, and wind velocity time series with resorting to weighted amplitude wave superposition (WAWS) was simulated.
Chunming, Wei, Bin, Ma, Tingting, Su
openaire   +2 more sources

Statistical Analysis of Wind-Induced Dynamic Response of Power Towers and Four-Circuit Transmission Tower-Line System [PDF]

open access: yesShock and Vibration, 2018
Only one wind field model loading the transmission tower or the tower-line system was investigated in the previous studies, while the influence of two different wind field models was not considered.
Xiaolei Zhang, Yanzhong Ju, Fuwang Wang
doaj   +2 more sources

Failure Risk Investigation of Transmission Tower-line System Under Sequential Earthquake Considering Input Directionality

open access: yes工程科学与技术
ObjectiveTransmission tower-line structures are representative spatial distribution systems. They typically span hundreds or even thousands of kilometers and inevitably traverse regions with high seismic intensities.
LIU Juncai, DONG You
doaj   +2 more sources

FE Simulation of Transmission Tower [PDF]

open access: yesAdvances in Civil Engineering, 2014
The vital components of the transmission line are the electrical transmission towers. They are commonly used to support the phase conductors and shield wires of a transmission line.
Boshra Eltaly, Amen Saka, Kamel Kandil
doaj   +2 more sources

Home - About - Disclaimer - Privacy