Results 161 to 170 of about 2,526,065 (280)

Uniform Amorphization of Crystalline Silicon Surfaces Enabled by Deep Ultraviolet Femtosecond Laser Pulses

open access: yesAdvanced Engineering Materials, EarlyView.
Deep‐UV (258 nm) femtosecond pulses enable uniform amorphous silicon writing on Si(100)/(111) with a six‐fold larger fluence amorphization window than NIR methods. Optimized fluence and overlap yield 20–45 nm uniform and continuous amorphous layers. Microscopy shows sharp interfaces, and real‐time reflectivity reveals nanosecond melt–resolidification ...
Wissal Benali   +5 more
wiley   +1 more source

All‐in‐One Analog AI Hardware: On‐Chip Training and Inference with Conductive‐Metal‐Oxide/HfOx ReRAM Devices

open access: yesAdvanced Functional Materials, EarlyView.
An all‐in‐one analog AI accelerator is presented, enabling on‐chip training, weight retention, and long‐term inference acceleration. It leverages a BEOL‐integrated CMO/HfOx ReRAM array with low‐voltage operation (<1.5 V), multi‐bit capability over 32 states, low programming noise (10 nS), and near‐ideal weight transfer.
Donato Francesco Falcone   +11 more
wiley   +1 more source

Printed Integrated Logic Circuits Based on Chitosan‐Gated Organic Transistors for Future Edible Systems

open access: yesAdvanced Functional Materials, EarlyView.
Edible electronics needs integrated logic circuits for computation and control. This work presents a potentially edible printed chitosan‐gated transistor with a design optimized for integration in circuits. Its implementation in integrated logic gates and circuits operating at low voltage (0.7 V) is demonstrated, as well as the compatibility with an ...
Giulia Coco   +8 more
wiley   +1 more source

Robust Electrocaloric Performance Enabled by Highly‐Polar Frustrated Nanodomains in NaNbO3‐Based Ferrodistortive Relaxor

open access: yesAdvanced Functional Materials, EarlyView.
P4bm framework in NaNbO3‐Ba(Ti, Hf)O3 ferrodistortive relaxor entails short‐range and highly‐polar ferrodistortive orders. The abundant highly‐polar orders facilitate to increase entropy change, and robust octahedral oxygen tilt enables to impede thermal perturbations.
Feng Li   +11 more
wiley   +1 more source

Self‐Sintering Ionogel Binder for Flexible, Recyclable, and Healable Printed Giant Magnetoresistive Sensors

open access: yesAdvanced Functional Materials, EarlyView.
ABSTRACT Electronic waste has emerged as a major environmental challenge, driven by the massive consumption and a limited lifetime of modern electronic devices, stimulating the development of sustainable electronics. Here, an all‐biomaterial gelatin‐choline‐citric acid ([Ch][CA]) ionogel is developed as an active binder to realize self‐sintered ...
Lin Guo   +10 more
wiley   +1 more source

Oxygen‐Tunnel Indium Tin Oxide Vertical Channel Transistors with Enhanced Current Density and Reliability for Monolithic 3D Compute‐In‐Memory Systems

open access: yesAdvanced Functional Materials, EarlyView.
Oxygen‐tunnel (OT) indium tin oxide (ITO) vertical channel transistors (VCTs) enable reliable, high‐density gain‐cell memory for monolithic 3D integration. A sandwiched SiN/SiO2/SiN OT stack selectively regulates oxygen transport, suppressing parasitic electrode oxidation while stabilizing channel oxygen vacancies, thereby suppressing carrier injection
Hyeonho Gu   +17 more
wiley   +1 more source

Corrigendum to "Residential exposure to transportation noise and risk of incident atrial fibrillation: a pooled study of 11 prospective Nordic cohorts" [The Lancet Regional Health - Europe, Volume 46, November 2024, 101091]. [PDF]

open access: yesLancet Reg Health Eur
Thacher JD   +40 more
europepmc   +1 more source

The Development of a Multiple-Item Annoyance Scale (MIAS) for Transportation Noise Annoyance. [PDF]

open access: yesInt J Environ Res Public Health, 2018
Schreckenberg D, Belke C, Spilski J.
europepmc   +1 more source

Regulated Ion‐Diffusion Hydrogels for Subtle and Multimodal Temperature‐Strain Sensing in Wound Monitoring

open access: yesAdvanced Functional Materials, EarlyView.
A soft, dual‐channel hydrogel patch enables simultaneous detection of wound temperature and strain by integrating ion‐diffusion‐mediated thermoelectric and resistive sensing. The conformal design maintains stable performance during motion, capturing subtle inflammatory and mechanical changes for continuous wound monitoring.
Yu Fang   +7 more
wiley   +1 more source

Home - About - Disclaimer - Privacy