Results 91 to 100 of about 7,046 (195)

Hemodynamic evaluation of anesthetized baboons and piglets by transpulmonary thermodilution: Normal values and interspecies differences with respect to xenotransplantation [PDF]

open access: yes, 2019
Background Transpulmonary thermodilution is well established as a tool for in-depth hemodynamic monitoring of critically ill patients during surgical procedures and intensive care.
Mayr, Tanja   +21 more
core   +1 more source

Cardiac output monitoring

open access: yesAnnals of Cardiac Anaesthesia, 2008
Minimally invasive and non-invasive methods of estimation of cardiac output (CO) were developed to overcome the limitations of invasive nature of pulmonary artery catheterization (PAC) and direct Fick method used for the measurement of stroke volume (SV).
Mathews Lailu, Singh Kalyan
doaj  

Application of transpulmonary thermodilution monitoring (PiCCO) in patient with neurogenic pulmonary edema and acute obstructive hydrocephalus due to a central neurocytoma: A case report

open access: yesInterdisciplinary Neurosurgery, 2017
Neurogenic pulmonary edema (NPE) is an acute life-threatening complication associated with many forms of central nervous system injury. Its pathophysiology is still debated.
Ryoichi Iwata   +5 more
doaj   +1 more source

sj-docx-1-jic-10.1177_08850666231160664 - Supplemental material for Adjunctive Hydrocortisone Improves Hemodynamics in Critically Ill Patients with Septic Shock: An Observational Study Using Transpulmonary Thermodilution

open access: yes, 2023
Supplemental material, sj-docx-1-jic-10.1177_08850666231160664 for Adjunctive Hydrocortisone Improves Hemodynamics in Critically Ill Patients with Septic Shock: An Observational Study Using Transpulmonary Thermodilution by Leonie Jochheim, David Jochheim,
Ulrich Mayr (533605)   +10 more
core   +1 more source

Accuracy of Cardiac Output by Nine DifferentPulse Contour Algorithms: A Comparison with Transpulmonary Thermodilution [PDF]

open access: yes, 2017
Heutzutage existieren zahlreiche verschiedene Pulskonturalgorithmen für die Bestimmung des Herzzeitvolumens (HZV). Das Ziel der vorliegenden Studie war die Untersuchung der Genauigkeit neun verschiedener Pulskonturalgorithmen im Vergleich zur ...
Masing, Sarah
core   +1 more source

Cardiac output monitoring: aortic transpulmonary thermodilution and pulse contour analysis agree with standard thermodilution methods in patients undergoing lung transplantation

open access: yes, 2003
Purpose: The PiCCO System is a relatively new device allowing intermittent cardiac output monitoring by aortic transpulmonary thermodilution technique (Aorta intermittent) and continuous cardiac output monitoring by pulse contour analysis (Aorta ...
M. G. Costa   +6 more
core   +2 more sources

Volkman’s Contracture, Persistent Limb Ischaemia, and Amputation: A Complication of Brachial Artery Catheterisation for Haemodynamic Monitoring Using PiCCO

open access: yesCase Reports in Critical Care, 2013
We report a case of a 64-year-old woman who was admitted to intensive care unit with multiorgan failure secondary to Plasmodium falciparum malaria. Haemodynamic monitoring using the transpulmonary thermodilution with pulse contour analysis system (PiCCO)
Veejay Bagga   +3 more
doaj   +1 more source

OXYGEN DELIVERY, GASES AND ACID-BASE BALANCE OF ARTERIAL BLOOD DURING XENON ANESTHESIA OF THE CLOSED CIRCU

open access: yesВестник анестезиологии и реаниматологии, 2018
Xenon is an inert gas being very close to an ideal anesthetic. Goal of the study: to evaluate changes in gases and acid-base balance of arterial blood during general xenon anesthesia with the closed circuit and to compare it with general anesthesia with ...
A. Yu. Kulikov   +2 more
doaj   +1 more source

Comparison of lung ultrasound with transpulmonary thermodilution in assessing extra-vascular lung water [PDF]

open access: yes, 2018
Background: Increased extra-vascular lung water (EVLW) is common in critical care and correlates with the severity of acute lung injury, length of intensive care unit stay and mortality. Lung ultrasound (LUS) can assess EVLW by determining the amount of ‘
Davids, Jody G.   +2 more
core  

Assessing fluid responses after coronary surgery: role of mathematical coupling of global end-diastolic volume to cardiac output measured by transpulmonary thermodilution [PDF]

open access: yes, 2009
Background Mathematical coupling may explain in part why cardiac filling volumes obtained by transpulmonary thermodilution may better predict and monitor responses of cardiac output to fluid loading than pressures obtained by pulmonary artery catheters ...
Breukers, R.B.G.E.   +6 more
core   +3 more sources

Home - About - Disclaimer - Privacy