Results 21 to 30 of about 7,046 (195)

COMPARISON OF DOPPLER ULTRASONOGRAPHY AND TRANSPULMONARY THERMODILUTION WHEN ANALYZING HEMODYNAMICS IN THE CHILDREN WITH SEVERE THERMAL INJURY [PDF]

open access: yesВестник анестезиологии и реаниматологии, 2017
Goal of the study: to compare rates of central hemodynamics, obtained through Doppler ultrasonography and transpulmonary thermodilution in the children with massive burns. Material.
A. U. Lekmanov   +2 more
doaj   +2 more sources

Interference of Continuous Renal Replacement Therapy on PiCCO Hemodynamic Monitoring: A Case Report. [PDF]

open access: yesClin Case Rep
ABSTRACT The proximity of the central venous and dialysis catheters during continuous renal replacement therapy can interfere with Pulse Index Continuous Cardiac Output hemodynamic measurements. Adjusting catheter placement or temporarily pausing continuous renal replacement therapy during measurement is essential to ensure accurate hemodynamic ...
Lin X, Suo Z, Liu X, Zhang H, Yuan Y.
europepmc   +2 more sources

The effects of differential injection sites of cold saline on transpulmonary thermodilution parameter values [PDF]

open access: yesPatient Preference and Adherence, 2015
Wanjie Yang,1 Qingguo Feng,1 Youzhong An,2 Xuefeng Zhao,1 Kai Wei,1 Chang Li,1 Wei Wang,1 Hongyun Teng1 1Department of Critical Care, The Fifth Central Hospital of Tianjin, Tianjin, People’s Republic of China; 2Department of Critical Care, The ...
Yang W   +7 more
doaj   +2 more sources

Extravascular lung water measurement using transpulmonary thermodilution in children [PDF]

open access: yesPediatric Critical Care Medicine, 2009
Measurement of extravascular lung water (EVLW) may be useful in the treatment of critically ill children and can be performed at the bedside using the transpulmonary thermodilution technique (TPTD). There are currently no data to verify the accuracy of these measurements in (small) children. We compared the results of TPTD measurement with the clinical
Lemson, J.   +4 more
openaire   +5 more sources

Transpulmonary Thermodilution in Neonates Undergoing Arterial Switch Surgery

open access: yesPediatric Cardiology, 2010
Measurement of the global end-diastolic volume index (GEDI) by transpulmonary thermodilution (TPTD) has become a useful technique for measuring preload in adults. This study aimed to investigate the hemodynamic changes in neonates during the postoperative period after arterial switch surgery.
Székely, Andrea   +7 more
openaire   +4 more sources

Approximation of EVLWI in severe COVID-19 pneumonia using quantitative imaging techniques: an observational study [PDF]

open access: yesIntensive Care Medicine Experimental
Background This study aimed to approximate the level of extravascular lung water (EVLW) in patients with severe COVID-19 pneumonia using quantitative imaging techniques.
Jonas Biehler   +12 more
doaj   +2 more sources

Assessment of cardiac output with transpulmonary thermodilution during exercise in humans

open access: yesJournal of Applied Physiology, 2015
The accuracy and reproducibility of transpulmonary thermodilution (TPTd) to assess cardiac output (Q̇) in exercising men was determined using indocyanine green (ICG) dilution as a reference method. TPTd has been utilized for the assessment of Q̇ and preload indexes of global end-diastolic volume and intrathoracic blood volume, as well as extravascular
Calbet, Jose A. L., Boushel, Robert
openaire   +4 more sources

Precision of the transpulmonary thermodilution measurements. [PDF]

open access: yesCrit Care, 2011
Abstract Introduction We wanted to determine the number of cold bolus injections that are necessary for achieving an acceptable level of precision for measuring cardiac index (CI), indexed global end-diastolic volume (GEDVi) and indexed extravascular lung water (EVLWi) by transpulmonary thermodilution.
Monnet X   +5 more
europepmc   +4 more sources

Cardiac output monitoring with pulmonary versus trans-cardiopulmonary thermodilution in left ventricular assist devices: Interchangeable methods?

open access: yesFrontiers in Physiology, 2022
Cardiac output (CO) measurement is mandatory in patients with left ventricular assist devices (LVADs). Thermodilution with pulmonary artery catheter (PAC) remains the clinical gold standard to measure CO in these patients, however it is associated with ...
Begoña Quintana-Villamandos   +6 more
doaj   +1 more source

Home - About - Disclaimer - Privacy