Results 151 to 160 of about 59,979 (305)

Pediatric Ocular Trauma in Iranshahr, Iran

open access: yes
Purpose: The aim of this article was to evaluate the characteristics, causes, and severity of pediatric ocular trauma in Iranshahr, Iran.Patients and Methods: This retrospective observational study analyzed pediatric ocular trauma (age < 12 years ...
Jamalzehi , Mojgan
core   +1 more source

Natural Biomaterials for Osteochondral Repair: From Source to Strategy

open access: yesAdvanced Healthcare Materials, EarlyView.
Biological origin‐guided overview of natural biomaterials and therapeutic strategies for osteochondral tissue engineering. The circular diagram categorizes representative materials and strategies into plant/algae‐derived, microbial‐derived, animal‐derived, and human‐derived sources, centered on an osteochondral defect repair model.
Hengyu Liu   +5 more
wiley   +1 more source

PEDIATRIC OCULAR TRAUMA

open access: yes, 2006
Ocular trauma is an important cause of ocular morbidity in children. At present only limited studies regarding distribution of ocular trauma exist in Iran.
M. R. Shoja A. M. Miratashi
core  

Gellan Gum Fluid Gel System for Controlled‐Delivery of Cytokine‐Licensed MSC‐EVs to Enhance Corneal Repair in Limbal Stem Cell Deficiency

open access: yesAdvanced Healthcare Materials, EarlyView.
Gellan gum fluid gel (FG) enables controlled ocular delivery of mesenchymal stromal cell (MSC)‐derived extracellular vesicles (EV). Its shear‐thinning, solid‐liquid‐solid rheology ensures prolonged ocular retention. Sustained MSC‐EV release (∼18% in 6 hrs) supports effective EV ocular delivery.
Seyedmohammad Moosavizadeh   +7 more
wiley   +1 more source

Bioinspired Adaptive Sensors: A Review on Current Developments in Theory and Application

open access: yesAdvanced Materials, EarlyView.
This review comprehensively summarizes the recent progress in the design and fabrication of sensory‐adaptation‐inspired devices and highlights their valuable applications in electronic skin, wearable electronics, and machine vision. The existing challenges and future directions are addressed in aspects such as device performance optimization ...
Guodong Gong   +12 more
wiley   +1 more source

Pseudophacocoele Following Blunt Ocular Trauma

open access: yes, 2011
Blunt ocular trauma may result in expulsion of the intraocular lens in a patient who has undergone cataract surgery. This case report describes a patient who presented with an extrusion of intraocular lens following blunt ocular trauma post-operatively ...
ZAINAB BINTI AWANG NGAH
core  

Rapid Fabrication of Self‐Propelled and Steerable Magnetic Microcatheters for Precision Medicine

open access: yesAdvanced Materials, EarlyView.
A rapid Joule heating fabrication method for the production of self‐propelling, adaptive microcatheters, with tunable stiffness and integrated microfluidic channels is presented. Demonstrated through three microrobotic designs, including a steerable guiding catheter, an untethered wave‐crawling TubeBot, and a distal‐end propelled microcatheter, it was ...
Zhi Chen   +5 more
wiley   +1 more source

Localized Temperature Monitoring in Mouse Brain during Light Delivery via a Non‐Planar Tapered Fiber‐Integrated µRTD Sensor

open access: yesAdvanced Materials, EarlyView.
We report a multifunctional tapered optical fiber integrating a conformal micro‐resistance temperature detector (µRTD) for local, real‐time thermometry during optical stimulation. The platform combines light‐delivery and temperature sensing within a minimally invasive footprint, enabling detection of sub‐degree cortical heating under representative ...
Antonio Balena   +6 more
wiley   +1 more source

In Vivo Monitoring of Thrombo‐Inflammatory Biomarkers via Molecularly Imprinted Polymer‐Integrated Hydrogel Microneedles

open access: yesAdvanced Materials, EarlyView.
A wearable electrochemical microneedle patch integrates Prussian Blue redox transduction with molecularly imprinted polymer recognition for reagent‐free sampling and detection of thrombo‐inflammatory biomarkers in dermal interstitial fluid. The platform tracks thrombin and inflammatory cytokines with sensitive in vitro, ex vivo, and in vivo performance,
Mahmoud Ayman Saleh   +11 more
wiley   +1 more source

Home - About - Disclaimer - Privacy