Results 331 to 340 of about 3,774,487 (407)

Geometric and dosimetric evaluation of a commercial AI auto‐contouring tool on multiple anatomical sites in CT scans

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Current radiotherapy practices rely on manual contouring of CT scans, which is time‐consuming, prone to variability, and requires highly trained experts. There is a need for more efficient and consistent contouring methods. This study evaluated the performance of the Varian Ethos AI auto‐contouring tool to assess its potential integration into
Robert N. Finnegan   +6 more
wiley   +1 more source

Dosimetric effect of silicone‐based gel on skin surface during volumetric modulated arc therapy for breast cancer

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose This study aims to quantify and compare the dosimetric effects of varying thicknesses of StrataXRT, a silicone‐based gel, and other topical agents on the skin surface during volumetric modulated arc therapy (VMAT) for breast cancer.
Tenyoh Suzuki   +13 more
wiley   +1 more source

Quantification and dosimetric impact of intra‐fractional bladder changes during CBCT‐guided online adaptive radiotherapy for pelvic cancer treatments

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose This study quantitatively evaluates bladder changes and their dosimetric impact during the on‐couch adaptive process on a commercial CBCT‐based online adaptive radiotherapy (CT‐gART) platform. Methods Data from 183 fractions of ten patients receiving online ART for pelvic cancers were analyzed retrospectively.
Ingrid Valencia Lozano   +7 more
wiley   +1 more source

Diagnostic image‐based treatment planning for online adaptive ultra‐hypofractionated prostate cancer radiotherapy with MR‐Linac

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose A new workflow was investigated for Elekta Unity MR‐Linac by removing the computed tomography (CT)‐simulation step and using diagnostic CT (DCT) for reference plan generation. Materials and methods Ten patients with ultra‐hypofractionated prostate cancer treated with magnetic resonance imaging (MRI)‐guided adaptive radiotherapy were ...
Yuan Xu   +5 more
wiley   +1 more source

Video Consultations for Patients Traveling Internationally for Medical Care: An Observational Study of a Tertiary Hospital in South Korea. [PDF]

open access: yesInt J Environ Res Public Health
Byun M   +10 more
europepmc   +1 more source

Position‐dependent offset corrections for ring applicator reconstruction in cervical cancer brachytherapy

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Due to the tight curvature in their design, ring applicators are usually associated with large positioning errors. The standard practice to correct for these deviations based on global offsets may not be sufficient to comply with the recommended tolerance.
Leon G. Aldrovandi   +3 more
wiley   +1 more source

Home - About - Disclaimer - Privacy