Results 141 to 150 of about 111,986 (258)
The morphologic variability in atrioventricular valvar atresia [PDF]
Anderson, RH, Rigby, ML, Ho, SY
core
ABSTRACT Aim In Fontan‐associated liver disease (FALD), chronic congestion often confounds conventional fibrosis markers, complicating surveillance for hepatocellular carcinoma (HCC). Although lymphatic dysfunction is fundamental to Fontan physiology, its contribution to hepatocarcinogenesis remains unclear.
Koji Imoto +14 more
wiley +1 more source
Abstract Background and Aims Systemic sclerosis (scleroderma; SSc) patients can develop pulmonary arterial hypertension (PAH), which is a leading cause of death. We sought to evaluate severity, therapeutic strategy and survival of SSc‐PAH in the Australian Scleroderma Cohort Study (ASCS).
Zoe Brown +13 more
wiley +1 more source
ABSTRACT Background The variable‐loop circular catheter (VLCC, VARIPULSE) is a pulsed‐field ablation (PFA) catheter equipped with a Tissue Proximity Indication (TPI) function, which monitors catheter‐tissue contact. Although TPI‐negative sites have been reported to contribute to gap formation, no studies have evaluated the utility of real‐time function.
Masataka Narita +9 more
wiley +1 more source
Mitral and tricuspid valve repair in a patient with eosinophilic granulomatosis with polyangiitis. [PDF]
Dąbrowska A +3 more
europepmc +1 more source
In anticoagulated atrial fibrillation, residual ischemic stroke risk persists despite guideline‐directed therapy. In this single‐center cohort, an enlarged index outpatient left atrial diameter independently predicted stroke and improved risk stratification when added to CHA2DS2‐VA (CHA2DS2‐VALa), supporting a simple, clinically implementable ...
Sefa Erdi Ömür +7 more
wiley +1 more source
ABSTRACT Background Electrographic flow (EGF) mapping is an FDA 510(k)‐cleared method for visualizing atrial activation wavefronts in atrial fibrillation (AF). Its clinical efficacy in detecting AF sources was demonstrated in the FLOW‐AF randomized controlled trial, and the underlying machine learning strategy used to develop and refine EGF source ...
Steven Castellano +9 more
wiley +1 more source
The necessity for surgeons to embrace transcatheter tricuspid valve therapy. [PDF]
Rachko JN, Malynowski E, Tang GHL.
europepmc +1 more source
ABSTRACT Introduction Patients with repaired tetralogy of Fallot (rTOF) remain at risk of ventricular tachycardia (VT). This risk is most commonly related to slow conduction within the septal isthmus, which is defined as the region between the ventricular septal defect (VSD) patch and adjacent valvular annuli.
Yuki Matsuoka +8 more
wiley +1 more source

