Results 101 to 110 of about 29,501 (235)

Feasibility and Safety on Left Bundle Branch Area Pacing With Standard Stylet‐Driven Lead: ACHIEVE‐SYNC Multicenter Prospective Observational Cohort Study

open access: yesJournal of Arrhythmia, Volume 42, Issue 3, June 2026.
In the prospective multicenter study, left bundle branch area pacing using stylet‐driven pacing leads demonstrated a high procedural success rate and showed stable lead performance during long‐term follow‐up. ABSTRACT Background Right ventricular pacing increases the risk of dyssynchrony, which raises the need for more physiological pacing strategies ...
Ga‐In Yu   +12 more
wiley   +1 more source

Transjugular tricuspid valve‐in‐ring replacement using the novel system under three‐dimensional printing guidance

open access: yesESC Heart Failure
Recurrent tricuspid regurgitation after failed ring annuloplasty is associated with high mortality rates and unfavourable clinical outcomes. Transcatheter tricuspid valve‐in‐ring (TVIR) replacement offers an alternative to high‐risk surgical reoperation,
Yiwei Wang, Yang Liu, Jian Yang
doaj   +1 more source

Use of a Melody Pulmonary Valve in Transcatheter Valve-in-Valve Replacement for Tricuspid Valve Bioprosthesis Degeneration

open access: yes, 2014
Bioprosthetic heart valves can degenerate and fail over time. Repeat surgery as a means of replacement increases morbidity and mortality rates, and some patients are not candidates for reoperation.
Shapiro, Brian P   +2 more
core   +1 more source

Acute Pericardial Effusion After Vein of Marshall Ethanol Infusion for Persistent Atrial Fibrillation

open access: yesJournal of Arrhythmia, Volume 42, Issue 3, June 2026.
This study reports a 25.2% incidence of acute pericardial effusion following vein of Marshall ethanol infusion for persistent atrial fibrillation. The extent of the resulting low‐voltage area was identified as an independent predictor of pericardial effusion, reflecting the magnitude of chemical injury.
Hualong Li   +4 more
wiley   +1 more source

Transcatheter Tricuspid Valve-in-Valve Replacement with an Edwards Sapien 3 Valve

open access: yes, 2017
A few case reports and case series have documented the outcomes in patients with tricuspid bioprosthetic valvular degeneration who underwent transcatheter implantation of the Medtronic Melody and the Edwards Sapien XT and Sapien 3 valves. In this report,
Pranav Loyalka   +11 more
core   +1 more source

Electrophysiological Characteristics of Atrial Fibrillation Trigger Sites During Ongoing Atrial Fibrillation Using Ultra‐High‐Resolution Mapping

open access: yesJournal of Arrhythmia, Volume 42, Issue 3, June 2026.
AF trigger sites exhibited a markedly shorter minimum local cycle length during ongoing AF, suggesting transient rapid activity. Ultra‐high‐resolution mapping during ongoing AF may provide complementary mechanistic information when conventional trigger mapping is inconclusive.
Kohki Nakamura   +10 more
wiley   +1 more source

Atrial Leadless Pacemaker Embolization to the Left Common Iliac Vein With Successful Retrieval: A Case Report

open access: yesJournal of Arrhythmia, Volume 42, Issue 3, June 2026.
A rare extracardiac complication in which a dislodged atrial leadless pacemaker migrated retrogradely to the left common iliac vein. This case highlights the role of venous anatomy in implantation difficulty and demonstrates successful device retrieval using a preventive strategy.
Toshihiko Goto   +4 more
wiley   +1 more source

Cardiovascular Health in Women—Across the Lifespan

open access: yesClinical Endocrinology, Volume 104, Issue 6, Page 539-555, June 2026.
ABSTRACT Cardiovascular disease (CVD) remains the leading cause of mortality and morbidity among women worldwide. However, CVD continues to be perceived as a predominantly male issue. CVD in women therefore remains understudied, underrecognized and undertreated.
Jaya Chandrasekhar   +5 more
wiley   +1 more source

Echocardiographic Imaging to Guide Tricuspid Interventions

open access: yesStructural Heart
Transcatheter tricuspid valve interventions may offer patients less invasive treatment alternatives to surgery. This review evaluates the use of echocardiography to determine anatomic suitability and guide the 2 most common classes of device currently ...
Rebecca T. Hahn, MD
doaj   +1 more source

Transcatheter Tricuspid Valve-in-Valve Replacement by Transatrial Approach

open access: yes, 2020
Reoperation on the tricuspid valve after prior heart valve surgery is associated with an increased operative risk due to a poor clinical status with severe heart failure and late presentation.
Raluca Ozana Chistol   +9 more
core   +1 more source

Home - About - Disclaimer - Privacy