Results 61 to 70 of about 853 (115)
Optimized Operation of an Existing Public Building Chilled Station Using TRNSYS
Taking an existing public building as an example, the mathematical model of each equipment module of the chilled station and the TRNSYS custom module are established on the basis of the measured data.
Ming Liu +5 more
doaj +1 more source
ASSESSMENT OF CLIMATE CHANGE IMPACT ON THE REQUIRED COOLING LOAD OF THE HOSPITAL BUILDINGS [PDF]
The impact of climate change on the energy performance of the Heating, Ventilation and Air Conditioning (HVAC) systems was studied in this research.
M. AHMADZADEHTALATAPEH, Y. H. YAU
doaj
UWG -TRNSYS Simulation Coupling for Urban Building Energy Modelling
This paper presents a new methodology to carry out building performance simulation at the district scale integrating the building thermal model TRNSYS with the climate model ‘Urban Weather Generator’ (UWG). The integrated methodology is designed to include the microclimatic modifications induced by urban environments on buildings’ cooling load ...
Massimo Palme, Agnese Salvati
openaire +2 more sources
Simulation of a Radiant Cooling System using Trnsys
In this study, a building in Shanghai is taken as the study object and the existing floor radiant cooling system of the building is simulated using Trnsys. Then, according to the actual condition of the building, a roof radiant cooling system is designed for the building which is compared to the floor radiant cooling system.
Fu Tongwei +3 more
openaire +1 more source
Le but de cet article, est l’étude thermique et énergétique du centre psychopédagogique ‘SAFAA’ qui se situe dans la ville d’Oujda (Maroc). A ce propos, des simulations ont été effectuées à l’aide du logiciel de simulation du comportement thermique en ...
R. Guechchati +3 more
doaj
Modelação energética de sistemas absorção em TRNSYS
Nas últimas décadas houve um rápido crescimento nas vendas dos equipamentos de ar condicionado e refrigeração, que se traduziu num crescente aumento do consumo energético. A utilização de energia solar para o arrefecimento representa um conceito atrativo uma vez que as necessidades de arrefecimento coincidem, na maior parte do tempo, com a ...
openaire +1 more source
Simulation of Prototype Active Agricultural Solar Dryer with Slit-Type Transpired Solar Collector
This paper presents a functional and easy method for simulation of thin bed drying of maize in an active solar dryer with slit-type transpired collector using TRNSYS software. Thin layer solar drying model written in TRNSYS equation blocks in combination
A. Kuhe +3 more
doaj
Experimental and simulated evaluation of inverse model for shallow underground thermal storage
This study employs an inverse grey-box (IGB) modeling approach, which combines measured data and the physics of systems to predict the performance of shallow underground thermal energy storage (UTES) with top and side insulation.
Fabian Eze +6 more
doaj +1 more source
Validated TRNSYS Model for Solar Assisted Space Heating System
The present study involves a validated TRNSYS model for solar assisted space heating system as applied to a residential building in Jordan using new detailed radiation models of the TRNSYS 17.1 and geometric building model Trnsys3d for the Google ...
Nidal Abdalla
doaj
Parameter identification manual for TRNSYS models at SERC
Ett tryckt exemplar finns i Högskolan Dalarnas arkiv.A printed copy can be found in Dalarna University's archives.