Results 51 to 60 of about 20,236 (253)
Background: Cycloplegic drops are commonly used in ophthalmology practice. Changes in anterior segment parameters may occur after cycloplegia. These changes can be evaluated with corneal topography. Objective: This study aimed to compare the effects of 1%
Mustafa Duran, Selim Cevher
doaj +1 more source
Effect of pharmacological pupil dilation on measurements and iol power calculation made using the new swept-source optical coherence tomography-based optical biometer [PDF]
Purpose: to determine whether pupil dilation affects biometric measurements and intraocular lens (IOL) power calculation made using the new swept-source optical coherence tomography-based optical biometer (IOLMaster 700©; Carl Zeiss Meditec, Jena ...
Almendral Gómez, Jaime +6 more
core +2 more sources
Abstract Background Non‐motor symptoms, especially autonomic dysfunction, are major contributors to disability and decreased quality of life in Parkinson's disease (PD). Despite being common and having a wide range of clinical facets, exocrine gland dysfunction is still not well recognized and managed.
Renato P. Munhoz +2 more
wiley +1 more source
Acute lens opacity induced by different kinds of anesthetic drugs in mice [PDF]
AIM: To study whether specific anesthetic drugs or tear layer evaporation was primarily responsible for the acute cataract and what the change of lens structure is in anesthetized mice.
Xiao-Tong Li +3 more
doaj +1 more source
Comparative lipid profiling dataset of the inflammation-induced optic nerve regeneration. [PDF]
In adult mammals, retinal ganglion cells (RGCs) fail to regenerate following damage. As a result, RGCs die after acute injury and in progressive degenerative diseases such as glaucoma; this can lead to permanent vision loss and, eventually, blindness ...
Bhattacharya, Sanjoy K +5 more
core +1 more source
A flexible arched artificial photoreceptor with high stability and biocompatibility was fabricated by integrating liquid crystal polymers with polyvinylidene fluoride‐trifluoroethylene. This device exhibits robust photoelectric responses under low‐intensity illumination and demonstrates efficacy in restoring visual responses in blind rats following ...
Yumeng Jiang +7 more
wiley +1 more source
Tropicamide ophthalmic solution reduces clozapine-induced sialorrhea: a case report
Clozapine-induced sialorrhea (CIS) is a common, treatment-limiting, and stigmatizing side effect. All systemic agents that are used for CIS may increase clozapine side effects such as blood pressure changes, constipation, or arrhythmias or may have a ...
Ozge Kilic +2 more
doaj +1 more source
Today, a variety of medications are used in ophthalmology practice to o produce cycloplegia and mydriasis. Purpose: to compare the extent of cycloplegia by residual accommodation response after instillations of various medications. Materials and methods.
N. A. Tarasova +3 more
doaj +1 more source
Purpose: The study was conducted to evaluate efficacy of intracameral lidocaine hydrochloride 1% and tropicamide injection 0.02% for anaesthesia and mydriasis in manual small-incision cataract surgery (MSICS) and to report any adverse drug reaction ...
Ketaki T Bhat +3 more
doaj +1 more source
Latanoprost with high precision, piezo-print microdose delivery for IOP lowering: clinical results of the PG21 study of 0.4 µg daily microdose. [PDF]
Background:Topical high-precision piezo-print delivery of microdoses of latanoprost achieved significant IOP reduction consistent with the eyedropper effect but with a 75% reduced exposure to drugs and preservatives.
Ianchulev, Tsontcho +5 more
core

