Analyst, The, 1988
The construction, characteristics and application of a laboratory-built coated tubular solid-state sulphide-selective electrode are described. Tygon tubing and silver foil are used to construct the tubular flow-through sensor. Treatment of the constructed tubular silver foil with a sodium sulphide solution yields an active membrane (volume, 15.7 µl ...
Jacobus F van Staden
exaly +2 more sources
The construction, characteristics and application of a laboratory-built coated tubular solid-state sulphide-selective electrode are described. Tygon tubing and silver foil are used to construct the tubular flow-through sensor. Treatment of the constructed tubular silver foil with a sodium sulphide solution yields an active membrane (volume, 15.7 µl ...
Jacobus F van Staden
exaly +2 more sources
Coated Tubular Ion-Selective Electrode Units in Process Systems
ECS Meeting Abstracts, 2014Dick (Richard) Buck made his mark in 1968 in the activity on ion-selective electrodes (ISEs) on the response of solid-state membrane electrodes under zero current conditions1 and in 1974 on concentration dependent selectivity coefficients for ion-selective electrodes2. I met Dick Buck in 1985 in the UK when I gave my first lecture on the new innovation
exaly +2 more sources
Mercury-coated tubular platinum electrode
Analytical Chemistry, 1967Thomas O. Oesterling, Carter L. Olson
exaly +2 more sources
Russian Journal of Applied Chemistry, 2015
It is advisable to use electrodeposited nickel-boron coatings to improve the corrosion resistance of the nickel coating on porous fibrous bases of tubular-plate nickel oxide electrodes of chemical power cells. It was found that a substantial nonuniformity of the current distribution and the coating thickness in deep and surface layers of the base is ...
V. V. Rogozhin +4 more
openaire +1 more source
It is advisable to use electrodeposited nickel-boron coatings to improve the corrosion resistance of the nickel coating on porous fibrous bases of tubular-plate nickel oxide electrodes of chemical power cells. It was found that a substantial nonuniformity of the current distribution and the coating thickness in deep and surface layers of the base is ...
V. V. Rogozhin +4 more
openaire +1 more source
Fresenius' Zeitschrift für analytische Chemie, 1988
A tubular solid-state lead(II)-selective electrode was prepared and constructed as a compact tubular sensor (volume 8.8 μl) from a lead tube and Tygon tubing. The lead/ lead sulphide membrane was activated by anodic deposition and conditioned in lead nitrate medium at pH 3.
openaire +1 more source
A tubular solid-state lead(II)-selective electrode was prepared and constructed as a compact tubular sensor (volume 8.8 μl) from a lead tube and Tygon tubing. The lead/ lead sulphide membrane was activated by anodic deposition and conditioned in lead nitrate medium at pH 3.
openaire +1 more source
Analytical Letters, 1986
Abstract A rapid and reliable automated procedure for the direct measurement of the chloride content in milk is described. The method is based on the principles of the flow-injection technique; a dialyzer is used to eliminate interferences and the dialyzed chloride is measured with a coated tubular chloride-selective electrode.
openaire +1 more source
Abstract A rapid and reliable automated procedure for the direct measurement of the chloride content in milk is described. The method is based on the principles of the flow-injection technique; a dialyzer is used to eliminate interferences and the dialyzed chloride is measured with a coated tubular chloride-selective electrode.
openaire +1 more source
Fresenius' Zeitschrift für analytische Chemie, 1986
The construction, incorporation and behaviour of a simple and cheap coated tubular solid-state iodide-selective electrode into the conduits of a flow-injection system is described. The compact tubular membrane FIA system is stable and once the electrode is established, it requires minimum maintenance.
openaire +1 more source
The construction, incorporation and behaviour of a simple and cheap coated tubular solid-state iodide-selective electrode into the conduits of a flow-injection system is described. The compact tubular membrane FIA system is stable and once the electrode is established, it requires minimum maintenance.
openaire +1 more source
The Analyst, 1990
The shape and quality of the analytical signal obtained from coated open-tubular inorganic-based solid-state ion-selective electrodes interfaced to a flow injection system are directly influenced by both the electrode and the flow injection system. The electrode characteristics and response, in a flow-through system, are controlled by the chemical ...
openaire +1 more source
The shape and quality of the analytical signal obtained from coated open-tubular inorganic-based solid-state ion-selective electrodes interfaced to a flow injection system are directly influenced by both the electrode and the flow injection system. The electrode characteristics and response, in a flow-through system, are controlled by the chemical ...
openaire +1 more source
Fresenius' Zeitschrift für analytische Chemie, 1988
The incorporation, behaviour and suitability of a simple and cheap home-made coated tubular solid-state silver(I)-selective electrode into the conduits of a flow-injection system is described. With 30 μl samples the flow-injection flow-through electrode system covers a working range up to 5000 mg/l.
openaire +1 more source
The incorporation, behaviour and suitability of a simple and cheap home-made coated tubular solid-state silver(I)-selective electrode into the conduits of a flow-injection system is described. With 30 μl samples the flow-injection flow-through electrode system covers a working range up to 5000 mg/l.
openaire +1 more source
The Analyst, 1992
An evaluation of the influence and contribution of the response times of coated open-tubular solid-state bromide- and chloride-selective electrodes on the analytical throughput (dispersion) in flow injection (FI) systems is presented using concentration ranges of 10–5000 mg dm–3 for bromide and chloride, respectively, in the study.
openaire +1 more source
An evaluation of the influence and contribution of the response times of coated open-tubular solid-state bromide- and chloride-selective electrodes on the analytical throughput (dispersion) in flow injection (FI) systems is presented using concentration ranges of 10–5000 mg dm–3 for bromide and chloride, respectively, in the study.
openaire +1 more source