Results 81 to 90 of about 94,000 (327)

Neurodevelopmental Disorder with Dystonia and Chorea Linked to De Novo Variants in the Splicing Regulator SRRM4

open access: yesMovement Disorders, EarlyView.
Abstract Background SRRM4 is an exclusively neural‐expressed splicing‐factor gene not yet associated with a monogenic condition. Objective We sought to delineate movement disorders caused by SRRM4 variants. De novo splice‐donor‐site variants at position +2 of intron 5 of SRRM4 (c.464+2T>C, c.464+2T>A) occurred in three unrelated patients with dystonia ...
Philip Harrer   +24 more
wiley   +1 more source

Optimizing Selective RF Pulses for Enhanced Signal Stability in Turbo Spin Echo Using a Differentiable Extended Phase Graph Model

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose To improve slice profile consistency across echo trains in turbo spin echo (TSE) imaging, thereby reducing image blurring and increasing the accuracy of multi echo spin echo T2$$ {T}_2 $$ mapping. Methods Excitation and refocusing RF pulses were optimized for TSE using a differentiable extended phase graph model that incorporates the ...
Madison M. Augelli   +3 more
wiley   +1 more source

Optimizing of Iterative Turbo Equalizer for Underwater Sensor Communication

open access: yesInternational Journal of Distributed Sensor Networks, 2013
We presented an iterative turbo equalization to cope with intersymbol interference induced by reflection of sea level and sea bottom for underwater sensor communication channel. Iterative turbo equalizer consists of inner codes and outer codes; we employ
Ji Won Jung, Ki Man Kim
doaj   +1 more source

Implementation of a Fully-Parallel Turbo Decoder on a General-Purpose Graphics Processing Unit

open access: yesIEEE Access, 2016
Turbo codes comprising a parallel concatenation of upper and lower convolutional codes are widely employed in the state-of-the-art wireless communication standards, since they facilitate transmission throughputs that closely approach the channel capacity.
An Li   +3 more
doaj   +1 more source

Performance Analysis and Enhancement of Multiband OFDM for UWB Communications

open access: yes, 2006
In this paper, we analyze the frequency-hopping orthogonal frequency-division multiplexing (OFDM) system known as Multiband OFDM for high-rate wireless personal area networks (WPANs) based on ultra-wideband (UWB) transmission.
Lampe, L., Schober, R., Snow, C.
core   +1 more source

A Hybrid RF Coil for Whole‐Brain Imaging in Non‐Human Primates at 7 T

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose Ultra‐high field MRI (≥ 7 T) offers unprecedented potential for mapping non‐human primate (NHP) brain function. However, complex electromagnetic systems are required to meet the challenges of UHF imaging and the mechanical demands of awake NHP studies.
Elias Djaballah   +5 more
wiley   +1 more source

Joint-Detection and Interference Cancellation Based Burst-by-Burst Adaptive CDMA Schemes

open access: yes, 2002
Spread adaptive quadrature amplitude modulated (AQAM) code-division multiple access (CDMA) is proposed as a powerful means of exploiting the time-variant channel capacity fluctuations of wireless channels.
Hanzo, L., Kuan, E.L., Ng, S.X.
core   +1 more source

Signal and Contrast Optimization With Predicted Excitations (SCOPE) for Accelerating Large FOV Body Imaging at UHF

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose Large FOV turbo‐spin‐echo (TSE) imaging at ultra‐high field (UHF) remains challenging due to B1+ inhomogeneity and peak specific absorption rate (pSAR) limitations. This work presents a new time‐interleaved acquisition of modes (TIAMO) framework called SCOPE (Signal and Contrast Optimization with Predicted Excitations), which overcomes
Tobey D. Haluptzok   +2 more
wiley   +1 more source

Time‐Conditioned Zero‐Shot Self‐Supervised Reconstruction for Accelerated 3D Ultra‐Low‐Field MRI

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose Ultra‐low‐field (ULF) MRI provides a cost‐effective, portable imaging option but has relatively low SNR and long acquisition times compared to standard clinical scans. This study presents a time‐conditioned zero‐shot self‐supervised learning image reconstruction framework (ULF‐ZS‐SSL) to accelerate 3D‐acquired single‐coil ULF MRI ...
Mart W. J. van Straten   +6 more
wiley   +1 more source

Improvement of Channel Coding System in Narrowband Communication System

open access: yesDianxin kexue, 2013
With the advantages of low complexity and easy implementation,convolution code is widely used in practical communication systems. However,the requirement of higher transmission power in tactical environment of long distance transmission and higher ...
Yanjun Wang, Jing Yue, Xue Cui
doaj   +2 more sources

Home - About - Disclaimer - Privacy