Results 81 to 90 of about 10,264 (176)
An increasing number of workers are facing various physical factors, such as heat stress due to the inevitable climate change. This study aimed to develop and validate an Outdoor Environmental Heat Index(OETI) without using measurement instruments ...
Habibollah Dehghan +2 more
doaj +1 more source
Objective To observe the effects of auricular magnetic bead pressing on maternal body temperature, inflammatory response and placental pathological results in epidural labor analgesia.
WEN Ting, LI Gan, CHEN Shi-biao, LIU Jia
doaj
Assessed Temperatures and Stress in Cats Using Tympanic and Rectal Thermometers
Previous studies using tympanic thermometers on pets have presented inconsistent conclusions. The first aim of the current study was to compare the assessed temperatures using tympanic and rectal thermometers on healthy cats in a home environment and in ...
Yrla Hanström +5 more
doaj +1 more source
Utilizing Tympanic Membrane Temperature for Earphone-Based Emotion Recognition
Emotion recognition by wearable devices is essential for advancing emotion-aware human–computer interaction in real life. Earphones have the potential to naturally capture brain activity and its lateralization, which is associated with emotion.
Kaita Furukawa +3 more
doaj +1 more source
[Axillary temperature compared to tympanic membrane temperature in children].
The purpose of the study was to measure the axillary temperature at three, six and nine minutes in a hundred children between the ages of one and twelve years who were selected in a non-random deliberate way, and to compare the measurements with the tympanic membrane temperature (golden standard) which was measured in the test persons at the same time.
G, Greyling, M J, Viljoen, G, Joubert
openaire +1 more source
A quasi-experimenal study was conducted to investigate the optimum time and accuracy of temperature measurements from four sites: rectum (2.5 cm and 3 cm beyond the anus in preterm and term neonates, respectively), axilla (with mercury-in-glass ...
V Jirapaet, W Lerthamtewe
doaj
A Predictive Model to Classify Undifferentiated Fever Cases Based on Twenty-Four-Hour Continuous Tympanic Temperature Recording. [PDF]
Dakappa PH +5 more
europepmc +1 more source
Accuracy and Precision of Third-Generation Tympanic Thermometers With Varying Calibration Intervals: A Multicenter Cross-Sectional Study. [PDF]
Morri M +11 more
europepmc +1 more source
Combined torso and foot heat exposure reduces acute <i>ad libitum</i> energy intake in young adults. [PDF]
Li G +7 more
europepmc +1 more source
Core temperature measurement methods and their accuracy in pediatric intensive care units: a narrative review. [PDF]
Chen H, Huang H, Ning J, Li Y, Qiao L.
europepmc +1 more source

