Results 111 to 120 of about 87,664 (270)

Magnetic Properties of Ab initio Model for Iron-Based Superconductors LaFeAsO

open access: yes, 2010
By using variational Monte Carlo method, we examine an effective low-energy model for LaFeAsO derived from an ab initio downfolding scheme. We show that quantum and many-body fluctuations near a quantum critical point largely reduce the antiferromagnetic
Aichhorn M.   +36 more
core   +1 more source

Multi‐Parametric MRI Approach at 3 T and 7 T for Assessing Skeletal Muscle Pathology in Myofibrillar Myopathies: A Pilot Study

open access: yesJournal of Cachexia, Sarcopenia and Muscle, Volume 17, Issue 2, April 2026.
ABSTRACT Background Myofibrillar myopathies (MFM) form a large group of clinically and genetically heterogeneous protein aggregate diseases. We investigated whether a novel quantitative MRI protocol can reveal new aspects of structural and biochemical muscle pathology in three classic MFM subtypes.
Claudius S. Mathy   +15 more
wiley   +1 more source

Experimental Research on Relationship between UHF Partial Discharge Signals and Discharge Quantity in GIS

open access: yesMATEC Web of Conferences, 2018
Apparent discharge quantity is usually recognized as judgement standard for severity of partial discharge in the field of electrical equipment insulation diagnosis.
Yang Tao   +10 more
doaj   +1 more source

Variability of the UHF Signals Generated by Partial Discharges in Mineral Oil

open access: yesSensors, 2019
The paper presents the results of the analysis on the variability of the ultra-high frequency (UHF) signals generated by partial discharges (PD) under the long-term AC voltage.
Michal Kunicki
doaj   +1 more source

Quantitative Confounder Analysis of Electrocardiogram Signals in Cardiac Magnetic Resonance at 1.5, 3 and 7 T—Assessing Standardized Electrode Positions and Sequence Types—Towards Quality Assurance

open access: yesJournal of Magnetic Resonance Imaging, Volume 63, Issue 4, Page 1140-1154, April 2026.
ABSTRACT Background The electrocardiogram (ECG) used for gating in cardiac MRI may be compromised by multiple confounders inside the scanner bore. Purpose To quantify the influence of magnetic field strengths (1.5 T/3 T/7 T), standardized electrode positions, and imaging sequences on ECG signals used for gating. Study Type Prospective.
Richard Hickstein   +10 more
wiley   +1 more source

Polyradical character and spin frustration in fullerene molecules: An ab initio non-collinear Hartree--Fock study

open access: yes, 2014
Most {\em ab initio} calculations on fullerene molecules have been carried out based on the paradigm of the H\"uckel model. This is consistent with the restricted nature of the independent-particle model underlying such calculations, even in single ...
Jiménez-Hoyos, Carlos A.   +2 more
core   +1 more source

Home - About - Disclaimer - Privacy