Research on Reactive Power Compensation Device in UHV AC Substation Connected Directly to 500 kV Busbar

open access: yesZhongguo dianli, 2019
Site selection is often difficult for the 1 000 kV UHV AC substation due to its many-grouped reactive power on the low-voltage side of main transformer and the large space occupation.
Lan GUAN   +5 more
doaj   +1 more source

Corona Loss Prediction of UHV AC Transmission Line Based on DBN Neural Network Optimized by PSO

open access: yesZhongguo dianli, 2022
Based on the correlation between corona loss of UHV AC transmission lines and weather conditions such as rainfall, specific humidity, temperature, relative humidity, pressure, etc., a corona loss prediction method for UHV AC transmission lines is ...
Shumin HUANG   +4 more
doaj   +1 more source

Observation of zigzag and armchair edges of graphite using scanning tunneling microscopy and spectroscopy

open access: yes, 2005
The presence of structure-dependent edge states of graphite is revealed by both ambient- and ultra-highvacuum- (UHV) scanning tunneling microscopy (STM) / scanning tunneling spectroscopy (STS) observations.
D. Papaconstantopoulos   +6 more
core   +1 more source

On‐Surface Indigo‐Based Bimolecular Coordination Networks with Programmable Regular or Vitreous Structure

open access: yesAdvanced Functional Materials, EarlyView.
A previously unreported coordination motif stabilising single Fe atoms by indigo chelation and pyridyl coordination on Au(111) has been revealed. By using planar tritopic pyridyl linkers (TPyB), extended 2D porous networks of indigo3(TPyB)2Fe6 form. These networks can be crystalline or vitreous and offer an environment where individual coordination ...
Hongxiang Xu   +9 more
wiley   +1 more source

Simulation Experiment on Discharge of Plastic Film Overlapping on UHVDC Transmission Lines

open access: yesZhongguo dianli, 2022
In order to study the discharge phenomena of plastic film overlapping on UHV DC transmission lines and explore the cause of flashover fault of a ± 800 kV UHV line, an experimental study is conducted on the flashover characteristics of plastic film with ...
Shenghui WANG   +3 more
doaj   +1 more source

Can Distribution Grids Significantly Contribute to Transmission Grids' Voltage Management?

open access: yes, 2016
Power generation in Germany is currently transitioning from a system based on large, central, thermal power plants to one that heavily relies on small, decentral, mostly renewable power generators.
Auer, Sabine   +4 more
core   +1 more source

A compact high-flux cold atom beam source [PDF]

open access: yes, 2011
We report on an efficient and compact high-flux Cs atom beam source based on a retro-reflected two-dimensional magneto-optical trap (2D MOT). We realize an effective pushing field component by tilting the 2D MOT collimators towards a separate three ...
Aveline, D. C.   +5 more
core   +3 more sources

MOFs and COFs in Electronics: Bridging the Gap between Intrinsic Properties and Measured Performance

open access: yesAdvanced Functional Materials, EarlyView.
Metal‐organic frameworks (MOFs) and covalent organic frameworks (COFs) hold promise for advanced electronics. However, discrepancies in reported electrical conductivities highlight the importance of measurement methodologies. This review explores intrinsic charge transport mechanisms and extrinsic factors influencing performance, and critically ...
Jonas F. Pöhls, R. Thomas Weitz
wiley   +1 more source

Hybrid Model of Power Transformer Fault Classification Using C-set and MFCM – MCSVM

open access: yesCSEE Journal of Power and Energy Systems
This paper aims to increase the diagnosis accuracy of the fault classification of power transformers by introducing a new off-line hybrid model based on a combination subset of the et method (C-set) & modified fuzzy C-mean algorithm (MFCM) and the
Ali Abdo   +6 more
doaj   +1 more source

Refined analysis on cross arm arrangement of a 1 000 kV UHV steel tube tower

open access: yesZhejiang dianli, 2023
In order to reduce the probability of damage to the cross arm of a 1 000 kV UHV steel tube tower, the general software TTA and the finite element software ANSYS are used for refined analysis on the internal force of the cross arm.
BAO Yunan   +5 more
doaj   +1 more source