Results 51 to 60 of about 14,640 (199)

Comparison of optimized soft‐tissue suppression schemes for ultrashort echo time MRI [PDF]

open access: yesMagnetic Resonance in Medicine, 2011
AbstractUltrashort echo time (UTE) imaging with soft‐tissue suppression reveals short‐T2 components (typically hundreds of microseconds to milliseconds) ordinarily not captured or obscured by long‐T2 tissue signals on the order of tens of milliseconds or longer.
Cheng, Li   +4 more
openaire   +2 more sources

MRI Visualization of Whole Brain Macro- and Microvascular Remodeling in a Rat Model of Ischemic Stroke: A Pilot Study [PDF]

open access: yes, 2020
Using superparamagnetic iron oxide nanoparticles (SPION) as a single contrast agent, we investigated dual contrast cerebrovascular magnetic resonance imaging (MRI) for simultaneously monitoring macro- and microvasculature and their association with ...
Cho, Hyungjoon   +3 more
core   +1 more source

Simple and robust saturation‐based slice selection for ultrashort echo time MRI [PDF]

open access: yesMagnetic Resonance in Medicine, 2014
PurposeTo present a new method for localizing signal within a two‐dimensional (2D) slice suitable for ultrashort echo time (UTE) imaging, called saturation‐based UTE (sat‐UTE). The new method digitally subtracts two acquisitions that are nonselectively excited with and without selective saturation of the slice of interest.MethodsSat‐UTE was compared ...
Kevin D, Harkins   +2 more
openaire   +2 more sources

Feasibility of ultrashort echo time quantitative susceptibility mapping with a 3D cones trajectory in the human brain

open access: yesFrontiers in Neuroscience, 2022
PurposeQuantitative susceptibility mapping (QSM) has surfaced as a promising non-invasive quantitative biomarker that provides information about tissue composition and microenvironment.
Hyungseok Jang   +12 more
doaj   +1 more source

In vivo UTE-MRI reveals positive effects of raloxifene on skeletal bound water in skeletally mature beagle dogs [PDF]

open access: yes, 2015
Raloxifene positively affects mechanical properties of the bone matrix in part through modification of skeletal bound water. The goal of this study was to determine if raloxifene induced alterations in skeletal hydration could be measured in vivo using ...
Allen, Matthew R.   +9 more
core   +1 more source

Effective Detection of Nafion®-Based Theranostic Nanocapsules Through 19F Ultra-Short Echo Time MRI

open access: yesNanomaterials, 2020
The application of the Three-Dimensional Ultra-Short Echo Time (3D UTE)pulse sequence at a high magnetic field for visualization of the distribution of 19F loaded theranostic core-shell nanocapsules with Nafion® (1,1,2,2-tetrafluoroethene; 1,1,2,2 ...
Natalia Łopuszyńska   +4 more
doaj   +1 more source

CKD Stages, Bone Metabolism Markers, and Cortical Porosity Index: Associations and Mediation Effects Analysis

open access: yesFrontiers in Endocrinology, 2021
Chronic kidney disease (CKD) has a significant negative impact on bone health. However, the mechanisms of cortical bone deterioration and cortical porosity enlargement caused by CKD have not been fully described.
Yan Xiong   +12 more
doaj   +1 more source

Quantifying temperature-dependent T1 changes in cortical bone using ultrashort echo-time MRI. [PDF]

open access: yesMagn Reson Med, 2015
To demonstrate the feasibility of using ultrashort echo-time MRI to quantify T1 changes in cortical bone due to heating.Variable flip-angle T1 mapping combined with 3D ultrashort echo-time imaging was used to measure T1 in cortical bone. A calibration experiment was performed to detect T1 changes with temperature in ex vivo cortical bone samples from a
Han M   +8 more
europepmc   +5 more sources

Ultrashort echo time (UTE) MRI for the assessment of caries lesions

open access: yesDentomaxillofacial Radiology, 2013
Direct in vivo MRI of dental hard tissues by applying ultrashort echo time (UTE) MRI techniques has recently been reported. The objective of the presented study is to clinically evaluate the applicability of UTE MRI for the identification of caries lesions.40 randomly selected patients (mean age 41 ± 15 years) were enrolled in this study.
Bracher, A-K   +8 more
openaire   +2 more sources

Applicator visualization using ultrashort echo time MRI for high-dose-rate endorectal brachytherapy [PDF]

open access: yesBrachytherapy, 2020
The individual channels in an endorectal applicator for high-dose-rate endorectal brachytherapy are not visible on standard MRI sequences. The aim of this study was to test whether an ultrashort echo time (UTE) MRI sequence could be used to visualize the individual channels to enable MR-only treatment planning for rectal cancer.We used a radial three ...
Ende, R.P.J. van den   +5 more
openaire   +3 more sources

Home - About - Disclaimer - Privacy