PurposeQuantitative susceptibility mapping (QSM) has surfaced as a promising non-invasive quantitative biomarker that provides information about tissue composition and microenvironment.
Hyungseok Jang +12 more
doaj +1 more source
High-Contrast Lumbar Spinal Bone Imaging Using a 3D Slab-Selective UTE Sequence
Ultra-short echo time (UTE) MRI with post-processing is a promising technique in bone imaging that produces a similar contrast to computed tomography (CT).
Amir Masoud Afsahi +10 more
doaj +1 more source
Direct magnitude and phase imaging of myelin using ultrashort echo time (UTE) pulse sequences: A feasibility study. [PDF]
He Q +6 more
europepmc +2 more sources
Measurement of T1 of the ultrashort T2* components in white matter of the brain at 3T. [PDF]
Recent research demonstrates that white matter of the brain contains not only long T2 components, but a minority of ultrashort T2* components. Adiabatic inversion recovery prepared dual echo ultrashort echo time (IR-dUTE) sequences can be used to ...
Bydder, Graeme M +6 more
core +7 more sources
Ultrashort echo time magnetization transfer (UTE‐MT) imaging of cortical bone [PDF]
Magnetization transfer (MT) imaging is one way to indirectly assess pools of protons with fast transverse relaxation. However, conventional MT imaging sequences are not applicable to short T2 tissues such as cortical bone. Ultrashort echo time (UTE) sequences with TE values as low as 8 µs can detect signals from different water components in cortical ...
Chang, EY +10 more
openaire +5 more sources
An Update in Qualitative Imaging of Bone Using Ultrashort Echo Time Magnetic Resonance
Bone is comprised of mineral, collagenous organic matrix, and water. X-ray-based techniques are the standard approach for bone evaluation in clinics, but they are unable to detect the organic matrix and water components in bone.
Saeed Jerban +6 more
doaj +1 more source
BACKGROUND AND PURPOSE CT is considered the modality of choice in the assessment of the skull due to the fast and accurate depiction of bone structures.
E. Deininger-Czermak +6 more
semanticscholar +1 more source
Whole-Brain Myelin Imaging Using 3D Double-Echo Sliding Inversion Recovery Ultrashort Echo Time (DESIRE UTE) MRI [PDF]
Background Signal contamination from long T2 water is a major challenge in direct imaging of myelin with MRI. Nulling of the unwanted long T2 signals can be achieved with an inversion recovery (IR) preparation pulse to null long T2 white matter within the brain. The remaining ultrashort T2 signal from myelin can be detected with an ultrashort echo time
Ya-Jun Ma +7 more
openaire +2 more sources
PurposeTo investigate the clinical feasibility of accelerated free-breathing stack-of-spirals (spiral) three-dimensional (3D) ultrashort echo time (UTE) lung magnetic resonance imaging (MRI) using iterative self‐consistent parallel imaging reconstruction
Min Jae Cha +6 more
doaj +1 more source