Results 31 to 40 of about 2,645,003 (172)

Veno-Venous Extracorporeal Membrane Oxygenation in Minipigs as a Robust Tool to Model Acute Kidney Injury: Technical Notes and Characteristics

open access: yesFrontiers in Medicine, 2022
ObjectiveVeno-venous extracorporeal membrane oxygenation (vv-ECMO) can save lives in severe respiratory distress, but this innovative approach has serious side-effects and is accompanied by higher rates of iatrogenic morbidity.
Antal Szabó-Biczók   +14 more
doaj   +1 more source

Method for measurement of wet gas in gas field by combining throttle flowmeter and vortex flowmeter

open access: yes, 2021
In order to solve the problem of single well without liquid phase measurement in Sulige Gas Field under the process mode of interwell series connection and wellhead wet gas measurement, a method of combining throttle flowmeter and vortex flowmeter to ...
Chuntao ZHANG   +4 more
core   +1 more source

CALIBRATION OF ULTRASONIC FLOWMETER FOR WI-FI NETWORK WITH THE HELP OF WEB BROWSER

open access: yesВестник Дагестанского государственного технического университета: Технические науки, 2019
Objectives. The purpose of the work was to change the method of signal transmission containing metrological information from industrial time-pulse ultrasonic gas flow meter to a compu-ting device (CD).
M. A. Velichko   +2 more
doaj   +1 more source

Tidal volume single breath washout of two tracer gases--a practical and promising lung function test. [PDF]

open access: yesPLoS ONE, 2011
BACKGROUND: Small airway disease frequently occurs in chronic lung diseases and may cause ventilation inhomogeneity (VI), which can be assessed by washout tests of inert tracer gas.
Florian Singer   +7 more
doaj   +1 more source

Development of a New Type Ultrasonic Gas Flowmeter

open access: yesDEStech Transactions on Social Science, Education and Human Science, 2017
In this paper, a new method on how to design ultrasonic gas flow meter is presented. Ultrasonic sensor with large area and center frequency 120kHz is selected and ultrasonic sensor driving circuit based on IRF7389 is designed to drive the sensor, the received ultrasonic signal can reach 1000mv in the distance of 30cm, thus can make the amplifying ...
Feng WAN, Xiao-Ming SHI
openaire   +2 more sources

A Simple Regeneration Process Using a CO2‐Switchable‐Polarity Solvent for Cellulose Hydrogels

open access: yesChemSusChem, Volume 18, Issue 6, March 15, 2025.
The effect of transformation of the anion chemical structure on cellulose solubility by flowing CO2 gas into aqueous pyrrolidinium hydroxide solutions was investigated. The changes in anion structure allowed for the modulation of cellulose solubility in aqueous pyrrolidinium hydroxide solutions, thus establishing a simple and safe cellulose ...
Arata Matsui   +5 more
wiley   +1 more source

Development of an Ultrasonic Airflow Measurement Device for Ducted Air [PDF]

open access: yes, 2015
In this study, an in-duct ultrasonic airflow measurement device has been designed, developed and tested. The airflow measurement results for a small range of airflow velocities and temperatures show that the accuracy was better than 3.5% root mean square
Andrew B. Raine   +9 more
core   +1 more source

Low‐Dimensional Materials and Van Der Waals Heterostructures for Energy Application: A Comprehensive Review

open access: yesENERGY &ENVIRONMENTAL MATERIALS, EarlyView.
Low‐dimensional materials (0D, 1D, and 2D) exhibit unique electronic and physicochemical properties, enabling advanced nanoelectronic and optoelectronic devices. Mixed‐dimensional heterostructures combine these materials to enhance functionality.
Qaisar Alam   +3 more
wiley   +1 more source

Method for optimizing the delivery process of natural gas ultrasonic flowmeters for verification

open access: yesYou-qi chuyun
[Objective] The delivery process of natural gas ultrasonic flowmeters for verification is not quantitative, and there are no relevant regulations on the scheduling and sequencing process before the flowmeters are put onto the inspection bench, resulting ...
HUANG Yongfei   +6 more
doaj   +1 more source

No evidence of higher peak heat tolerance in the afternoon or with opportunity for thermal behaviour during low‐intensity work in uncompensable heat

open access: yesExperimental Physiology, EarlyView.
Abstract Heat tolerance is known to be limited by high brain temperature, but most findings pertain to strenuous exercise following artificially altered baseline temperature or with limited opportunity for behaviour. Therefore, we investigated the hypotheses that thermal perceptions, hyperventilation and cerebrovascular responses would be exacerbated ...
Tiarna Stothers   +5 more
wiley   +1 more source

Home - About - Disclaimer - Privacy