Directed energy deposition (DED) has a widely application prospect, but dendrite and component segregation are not easily controlled and predicted. In this study, the method of applying ultrasonic assisted rolling was introduced to the DED to eliminate ...
Hao Li +5 more
doaj +1 more source
Ultrasonic roll bite measurements in cold rolling – Roll stress and deformation [PDF]
In cold rolling of thin metal strip, contact conditions between the work rolls and the strip are of great importance: roll deformations and their effect on strip thickness variation may lead to strip flatness defects and thickness inhomogeneity. To control the process, several online measurements are usually carried out such as the rolling load ...
Carretta, Yves +6 more
openaire +3 more sources
Two new surface strengthening processes,Ultrasonic rolling treatment before and after quenching were investigated on GCr15 steel. The surface integrity and corrosion were tested and ABAQUS simulation was conducted for the two processes.
Yongchen Wang +3 more
doaj +1 more source
Microstructural evolution and surface integrity of ultrasonic surface rolling in Ti6Al4V alloy
Ultrasonic surface rolling technology is a new mechanical surface treatment technology that can improve the surface integrity, increase the amplitude and depth of the residual compressive stress layer and improve the fatigue property of metal materials ...
Xian Luo +4 more
doaj +1 more source
Effect of ultrasonic rolling on local corrosion induced by second phase of 6061 aluminum alloy
USRP (ultrasonic surface rolling processing) was used to change the surface layer of 6061 aluminum alloy, so as to realize the change of the second phase microstructure of 6061 aluminum alloy by USRP under different static pressure conditions to improve ...
FAN Lei +8 more
doaj +1 more source
Acoustic measurement of lubricant-film thickness distribution in ball bearings [PDF]
An oil-film thickness monitoring system capable of providing an early warning of lubrication failure in rolling element bearings has been developed. The system is used to measure the lubricant-film thickness in a conventional deep groove ball bearing ...
Bruce W. Drinkwater +7 more
core +1 more source
Monitoring of lubricant film failure in a ball bearing using ultrasound [PDF]
A lubricant-film monitoring system for a conventional deep groove ball bearing (type 6016, shaft diameter 80 mm, ball diameter 12.7 mm) is described. A high-firequency (50 MHz) ultrasonic transducer is mounted on the static outer raceway of the bearing ...
Anderson +21 more
core +1 more source
Correlating Ultrasonic Velocity in DC04 with Microstructure for Quantification of Ductile Damage
The detection of ductile damage by image-based methods is time-consuming and typically probes only small areas. It is therefore of great interest for various cold forming processes, such as sheet-bulk metal forming, to develop new methods that can be ...
Steffen Wackenrohr +4 more
doaj +1 more source
A method for the measurement of hydrodynamic oil films using ultrasonic reflection [PDF]
The measurement of the thickness of an oil film in a lubricated component is essential information for performance monitoring and control. In this work, a new method for oil film thickness measurement, based on the reflection of ultrasound, is evaluated ...
Drinkwater, B.W. +2 more
core +1 more source
Effect of Pressing Amount in High-Temperature Assisted Ultrasonic Deep Rolling on Microstructure and Properties of Cermet Coatings [PDF]
In order to further improve the coating microstructure and properties,a new surface micro-crystallization technique,high temperature assisted ultrasonic deep rolling (HT+UDR), was used to treat the cermet coating, which could soften the cermet coating by
ZHANG Jun, ZHAO Yuncai, HE Yang, ZHANG Xinyu, MENG Cheng
doaj +1 more source