AlScN Film Based Piezoelectric Micromechanical Ultrasonic Transducer for an Extended Long-Range Detection. [PDF]
Yang H +5 more
europepmc +1 more source
We report the development of biotinylated PEGylated bilirubin‐coated perfluoropentane (bt‐PEG‐BR@PFP) nanobubbles, a novel class of ROS‐activatable and dual‐modality contrast agents that amplify both ultrasound (US) and magnetic resonance imaging (MRI) signals in response to elevated ROS.
Wonsik Jung +6 more
wiley +1 more source
Advances in Crosstalk Reduction Techniques for Ultrasonic Transducer Arrays. [PDF]
Boujenoui A +4 more
europepmc +1 more source
Photoacoustic imaging of visually evoked cortical and subcortical hemodynamic activity in mouse brain: feasibility study with piezoelectric and capacitive micromachined ultrasonic transducer (CMUT) arrays. [PDF]
Chang KW +5 more
europepmc +1 more source
Mechanozyme: An Artificial Enzyme With a Mechanophore Framework
Mechanical destabilization of a G‐quadruplex mechanophore in a DNAzyme markedly boosts its catalytic activity, demonstrating “mechanozymes” as artificial enzymes whose functions are modulated by mechanical stress exerted by ultrasonication. This mechanozyme principle is broadly applicable to control biomolecular activities.
Jiahao Ji +7 more
wiley +1 more source
Integrated system for ultrasonic, elasticity and photoacoustic imaging
textBy integrating three complementary imaging techniques - ultrasound, elasticity and photoacoustic imaging, a hybrid imaging system utilizing an array transducer is proposed for various biomedical imaging applications including cancer detection ...
Park, Suhyun, 1977-
core
Design of a Novel Electromagnetic Ultrasonic Transducer for Stress Detection. [PDF]
Chen C, Xu C, Yang G, Ma Y, Yang S.
europepmc +1 more source
Fabrication and DC-Bias Manipulation Frequency Characteristics of AlN-Based Piezoelectric Micromachined Ultrasonic Transducer. [PDF]
Li T +7 more
europepmc +1 more source
Noninvasive Focal Gene Delivery into the Cerebellum of Non‐Human Primates using Focused Ultrasound
Focal and non‐invasive viral vector delivery in non‐human primates remains a major challenge in translational neuroscience. Low‐intensity focused ultrasound was used to transiently open the blood–brain barrier and enable targeted gene delivery to the cerebellum.
Noelia Esteban‐García +11 more
wiley +1 more source
Auto-positioning ultrasonic transducer system
An ultrasonic transducer apparatus and process for determining the optimal transducer position for flow measurement along a conduit outer surface. The apparatus includes a transmitting transducer for transmitting an ultrasonic signal, said transducer ...
Buchanan, Randy K.
core

