Results 21 to 30 of about 24,482 (255)
Study on a novel omnidirectional ultrasonic cavitation removal system for Microcystis aeruginosa
Microcystis aeruginosa, as a typical alga, produces microcystin with strong liver toxicity, seriously endangering the liver health of human and animals. Inhibiting the bloom of the Microcystis aeruginosa in lakes becomes a significant and meaningful work.
Hao-Ren Feng +5 more
doaj +1 more source
In ultrasonic array imaging, 3D ultrasonic wavefields are normally recorded by an ultrasonic piezo array transducer. Its performance is limited by the configuration and size of the array transducer.
Xing Wang +4 more
doaj +1 more source
Two-Dimensional Photoacoustic/Ultrasonic Endoscopic Imaging Based on a Line-Focused Transducer
Existing acoustic-resolution photoacoustic/ultrasonic endoscopy (PA/USE) generally employs a point-focused transducer for ultrasound detection, which is only sensitive in its focal region, thus the lateral resolution and sensitivity drop dramatically ...
Weiran Pang +6 more
doaj +1 more source
Usually for non-destructive testing at high temperatures, ultrasonic transducers made of PZT and silver electrodes are used, but this could lead to damage to or malfunction of the ultrasonic transducer due to poor adhesion between PZT and silver ...
Vaida Vaskeliene +4 more
doaj +1 more source
Functional Materials for ICE and IVUS Piezoelectric Transducers: A Review
This review paper provides a comprehensive overview of the functional materials and assembly technologies used in intracardiac echocardiography (ICE) and intravascular ultrasound (IVUS) transducers.
Dayong He, Baihezi Ye
doaj +1 more source
Ultrasonic Detection of Transversal Cracks in Rail Heads – Theoretical Approach
In the paper the calculation of ultrasonic field generated by the transmitting transducer and the pulse-echo amplitude received after beam reflection at the defect in tested material is presented.
Tomasz KATZ +4 more
doaj +1 more source
Capacitive Micromachined Ultrasonic Transducers (CMUTs) for Underwater Imaging Applications
A capacitive micromachined ultrasonic transducer structure for use in underwater imaging is designed, fabricated and tested in this paper. In this structure, a silicon dioxide insulation layer is inserted between the top electrodes and the vibration ...
Jinlong Song +8 more
doaj +1 more source
Air-coupled ultrasonic transducers based on novel piezoelectrets with extremely small acoustic impedance have some distinctive advantages including no coupling agent, flexibility, and eco-friendliness, compared to conventional ultrasonic transducers ...
Feng Li +4 more
doaj +1 more source
This study identifies somatostatin receptor 4 (Sstr4) as a critical tumor suppressor against skin and head/neck cancers (HNSCC, cSCC, and BCC). The loss of Sstr4 removes a check on cell growth, causing hyperactivation of the MAPK‐ERK signaling pathway (↑).
Ali Taqvi +6 more
wiley +1 more source
Design of a Longitudinal-Bending Elliptical Vibration Ultrasonic Transducer with a Bent Horn
The thin and straight horn of the ultrasonic transducer is located in the center of the thick transducer, so that the tool tip of the ultrasonic vibration turning tool holder cannot be located on the outermost side of the entire tool holder, which leads ...
Zhiyong Huang +5 more
doaj +1 more source

